Testing the complete configuration
Testing terminating trunk transmission
The terminating trunk transmission test provides for extension number access to 3 tone sequences that can be used for trunk transmission testing from the distant end of the trunks. To test terminating trunk transmission:
1.Type change
2.Under TERMINATING TRUNK TRANSMISSION TEST (Extension), type in 3 extension numbers in the 3 fields provided:
Test Type 100:_______Test Type 102:_______Test Type 105:_______
Test type | Test features |
|
|
Test type 100
Test Type 102
5.5 seconds of 1004 Hz tone at 0 dB
Quiet until disconnect; disconnect is forced after 1 minute
9 seconds of 1004 Hz tone at 0 dB
1 second of silence
Cycle is repeated until disconnect, which is forced after 24 hours
Test Type 105
9 seconds of 1004 Hz tone at
9 seconds of 404 Hz tone at
9 seconds of 2804 Hz tone at
0.5seconds of test progress tone (2225 Hz) About 5 seconds of silence
Forced disconnect