808A Emergency Transfer Panel and telephone installation examples

4.Connect ST leads on the yellow emergency transfer row/connecting block for each emergency transfer telephone to the assigned terminal in the blue or white station distribution field. The ST terminal leads should be terminated on the following pairs: 1, 4, 7, 10, 13, 16, 19, or 22 (the first pair of any 3-pair group).

5.Install the telephone:

Connect telephone to the information outlet.

Install patch cords/jumper wires between the media gateway side and the station side of the station distribution field on the MDF.

Installing telephones used for emergency

transfer and as normal extension (trunk/auxiliary field)

To install telephones used for emergency transfer and as a normal extension:

1.Connect a pair of wires between the -48Vand GRD terminals on the yellow emergency transfer row/connecting block to the EM TRANS RELAY PWR terminal. See

Figure 50: Connections for telephone used for emergency transfer and as normal extension on page 104.

2.Connect CO trunk leads from the purple field to TC terminals on the yellow emergency transfer row/connecting block for each trunk.

3.Connect CO trunk leads from the green field to TK terminals on the yellow emergency transfer row/connecting block for each trunk.

4.Connect telephone leads from the purple analog line circuit pack row/ connecting block to the LC terminals on the yellow emergency transfer row/connecting block for each telephone.

5.Connect ST leads on the yellow emergency transfer row/connecting block for each emergency transfer telephone to the assigned terminal in the blue or white station distribution field.

6.Install the telephone:

Connect telephone to the information outlet.

Install patch cords/jumper wires between the media gateway side and the station.

Issue 3 January 2008 105

Page 105
Image 105
Avaya 03-300686 manual Issue 3 January 2008