Installing and wiring telephones and trunks
78 Installing and Connecting the MDF and Telephones
Figure 38: Digital Tie Trunk wiring
DS1 tie trunk example
Digital Signal Level 1 (DS1) tie trunks provide a 1.544 Mbps (T1) or 2.048 Mbps (E1) digital data
service between two collocated configurations or between the configuration and a data network.
See these examples:
Collocated DS1 interface trunks on page 78
DS1 interface trunks using T1 channel service unit on page 79
For cable descriptions, see
DS1 cables on page 80
Pinout of C6F cable on page 80
Collocated DS1 interface trunks
Two TN464HP DS1 Interface circuit packs can be in collocated configurations. A DS1 Interface
circuit pack in one configuration can be connected to a DS1 in another configuration. A C6D
cable can be used if the distance is less than 50 feet (15.2 meters). If the distance is between
50 feet (15 meters) and 1,310 feet (399 meters), use a C6E cable.
Note:
Note: The maximum distance between cabinets is 1,310 feet (399 meters).
Figure notes:
1. External Trunk
2. Digital Trunk Circuit Pack
3. LO
4. LO (Balanced Output Pair)
5. LI
6. LI (Balanced Input Pair)