Media gateway connections to the MDF

Figure 12: Equipment room cabling labels

1 A 2

 

 

A

 

 

 

 

labels LJK 060396

Figure notes:

 

 

1.

Purple Label (Port Cable)

3.

Yellow Label (Auxiliary)

2.

Blue/Yellow Label (Building

4.

Blue/Yellow Label (Site or

 

and Floor)

 

Satellite)

 

 

 

 

The top blue/yellow building and floor labels are for cables connecting from the equipment room to a site/satellite location on another floor or in another building. The yellow label is for auxiliary circuits connecting to the trunk/auxiliary field. The bottom blue/yellow label is for 25-pair cables connecting to site/satellite closets. See Table 2: Equipment room labels.

Table 2: Equipment room labels

Label name

Range

 

 

Port Cable

1A1-1A20, 1B1-1B20,

 

1C1-1C20, 1D1-1D20,

 

1E1-1E20

 

 

Building

Field Identified

 

 

Floor

Field Identified

 

 

Auxiliary Cable

Field Identified

 

 

Site or Satellite

A-F and/or Field Identified

 

 

34 Installing and Connecting the MDF and Telephones

Page 34
Image 34
Avaya 03-300686 manual Equipment room cabling labels