Connecting telephones

Figure 35: 400B2 Adapter connecting to a modular plug

 

 

 

r749428 KLC 060396

Figure notes:

 

 

1.

Flush-Mounted Information Outlet

4.

400B2 Adapter

2.

Surface-Mounted Information

5.

To Telephone

 

Outlet

6.

Destination Service Access Point

3.

To Individual Power Unit

 

(DSAP) Power Cord

 

 

 

 

Connecting an analog station or 2-wire digital station

This example is typical of the 2-wire digital stations (2420, 64xx, 302D), 2-wire analog stations (2500), analog central office (CO) trunks, direct inward dial (DID) trunks, and external alarms. See Figure 36: 2500-type analog telephone wiring on page 76.

To connect an analog station or 2-wire digital station:

1.Choose a peripheral to connect (such as a 2-wire digital station).

2.Choose the media module to use and its media gateway and slot number. For example: MM711 Analog Media Module, Media Gateway 002, Slot V2.

3.Choose a port circuit on the MM711 Media Module, for example port 03.

4.Install cross-connect jumpers to connect the pins from the 2-wire digital station to the appropriate pins on the MM711 Media Module. Table 8: Station pinout chart on page 76 shows a printout chart for two-wire stations.

5.Administer using Administrator Guide for Avaya Communication Manager (03-300509).

Issue 3 January 2008 75

Page 75
Image 75
Avaya 03-300686 manual Connecting an analog station or 2-wire digital station, 400B2 Adapter connecting to a modular plug