Installing and wiring telephones and trunks
Installing external ringing
Connections for external ringing are at an information outlet. The media gateway side of the MDF is connected to a TN2183 (or equivalent) Analog Line circuit pack. The circuitry and power source for the device are provided by the customer.
Note:
A maximum of three devices can connect to one analog line circuit pack port. To install external ringing:
1.Wire the ringing device to the information outlet as shown in Figure 51:
modularity on page 106 and Figure 41: Example adjunct power connections on page 85.
2.Administer per the Administrator Guide for Avaya Communication Manager
Figure 51: 3-pair and 4-pair modularity
Figure notes: |
|
| |
1. | Port Circuit Pack | 4. | Input to Information Outlet |
2. | Media Gateway Connector Pins |
|
|
| 5. | Adjunct Power | |
3. | Main Distribution Frame (MDF) | 6. | Output From Information Outlet |
| Pins |
| |
|
| 7. | Voice or Data Terminal Pins |
|
|
|
|