Installing and wiring telephones and trunks

Installing external ringing

Connections for external ringing are at an information outlet. The media gateway side of the MDF is connected to a TN2183 (or equivalent) Analog Line circuit pack. The circuitry and power source for the device are provided by the customer.

Note:

A maximum of three devices can connect to one analog line circuit pack port. To install external ringing:

1.Wire the ringing device to the information outlet as shown in Figure 51: 3-pair and 4-pair

modularity on page 106 and Figure 41: Example adjunct power connections on page 85.

2.Administer per the Administrator Guide for Avaya Communication Manager (03-300509).

Figure 51: 3-pair and 4-pair modularity

Figure notes:

 

 

1.

Port Circuit Pack

4.

Input to Information Outlet

2.

Media Gateway Connector Pins

 

(4-Pair Modularity)

 

(3-Pair Modularity)

5.

Adjunct Power

3.

Main Distribution Frame (MDF)

6.

Output From Information Outlet

 

Pins (3-Pair Modularity)

 

(4-Pair Modularity)

 

 

7.

Voice or Data Terminal Pins

 

 

 

 

106 Installing and Connecting the MDF and Telephones

Page 106
Image 106
Avaya 03-300686 manual Installing external ringing, Pair and 4-pair modularity