Installing and wiring telephones and trunks
Attendant console example
Perform these tasks to install an attendant console
●Installing the attendant console on page 87
●Installing the 26B1 Selector Console on page 88
Attendant console cabling distances, local and phantom power
A console’s maximum distance from the media gateway is limited. The maximum distance for a 302D console is as shown in Table 13: Attendant console cabling distances.
Table 13: Attendant console cabling distances
Enhanced Attendant | 24 AWG wire | 26 AWG wire | ||
Console (302D) | (0.5106 mm2) | (0.4049 mm2) | ||
| Feet | Meters | Feet | Meters |
|
|
|
|
|
With Selector Console |
|
|
|
|
|
|
|
|
|
Phantom powered | 800 | 244 | 500 | 152 |
|
|
|
|
|
Locally powered | 5,000 | 1,524 | 3,400 | 1,037 |
|
|
|
|
|
Without Selector Console |
|
|
|
|
|
|
|
|
|
Phantom powered | 1,400 | 427 | 900 | 274 |
|
|
|
|
|
Locally powered | 5,000 | 1,524 | 3,400 | 1,037 |
|
|
|
|
|
Auxiliary power
!
CAUTION:
Do not use the 329A power unit for the attendant console.
The nonessential functions of an attendant console and its optional 26A1 or 24A1 selector console derive their power from an auxiliary power source. Of the maximum of 27 attendant consoles, 3 of the consoles can derive auxiliary power from the media gateway and through the auxiliary cable located in the trunk/auxiliary field. Provide auxiliary power for a primary attendant console through this cable so the console remains fully operational during short power outages.