Installing the main distribution frame

Mounting 110P-type terminal blocks on a frame

The 900-pair 110P-type terminal blocks and the associated patch cord troughs can also be mounted on a free-standing, floor-mounted 1110A2 Apparatus Mounting Frame. See Figure 7: 1110A2 and 1110C1 apparatus mountings on page 24.

Each 1110A2 provides the space to mount five terminal blocks/patch cord troughs on each side of the frame. A cable support structure, apparatus mounting 1110C1, mounts directly on top of the 1110A2 and provides support for all cables routed to and from the frame. See

Table 1: Apparatus mounting frame ordering information on page 25.

Figure 7: 1110A2 and 1110C1 apparatus mountings

 

 

 

r781401 LJK 040896

Figure notes:

 

 

1.

1110C1 Apparatus Mounting

4.

88.5 inches (225 centimeters)

2.

1110A2 Apparatus Mounting

5.

43.5 inches (110.5 centimeters)

3.

76 inches (193 centimeters)

 

 

 

 

 

 

24 Installing and Connecting the MDF and Telephones

Page 24
Image 24
Avaya 03-300686 manual Mounting 110P-type terminal blocks on a frame, 1110A2 and 1110C1 apparatus mountings