Baldor GLC25, GLC10, GLC60 Program Menus, Battery Voltage/Engine Speed, Tachometer, Read Only Mode

Models: GLC40 GLC25 GLC15 GLC100 GLC30 GLC65 GLC20 GLC45 GLC105 GLC60 GLC10

1 114
Download 114 pages 7.44 Kb
Page 64
Image 64

Engine Parameter Display Two engine operating parameter screens are provided.

Battery Voltage/Engine Speed

BATTERY

27.0 Vdc

 

(Tachometer)

 

SPEED

1800 rpm

 

 

 

 

 

Battery

Displays battery voltage in DC volts. The voltage is displayed with a resolution of 1/10 of a volt.

Speed

Displays engine speed in revolutions per minute (RPM).

Engine Temperature/Oil Pressure

ENG TEMP

57 Deg C

OIL PRESS

200 KPA

ENG TEMP

Displays engine temperature in either degrees Celsius or Fahrenheit (as selected).

OIL PRESS

Displays engine oil pressure in either pounds per square inch (PSI) or in Kilopascals (KPA) (as selected).

Program Menus

Program Menu

The programming menu is used to change values such as time delays, analog fault settings, digital fault settings. Access to the programming sub-menus may only be obtained with a security password number. The sub menus are organized as follows:

PROGRAM MENU?

NO

Displays two messages that may be toggled between YES and NO by pressing the INCREMENT push-button. NO Programming sub-menus are disabled when NO is displayed.

YES Programming sub-menus are enabled when YES is displayed and a valid password number is entered.

PASSWORD

0

Press INCREMENT or DECREMENT to change the password. Press ENTER when the correct number is displayed.

Read Only Mode

User can view the parameters but cannot change any values. The factory setting for this level is one (1).

Read / Write Mode

User can view and modify any parameter value. The factory setting for this level is two (2).

Master Read / Write Mode

User can view and modify any parameter value and view/modify the security password level numbers. Contact Baldor for master password if required.

The values of the parameter settings for your generator-set can be recorded for future reference using the Configuration Data Sheet shown in Figure 4‐16.

After the correct password number is entered, the you may choose one of four programming menus. Press INCREMENT or DECREMENT to find the desired menu then press ENTER.

MAIN MENU LOOP

ANALOG FAULT MENU LOOP

DIGITAL FAULT MENU LOOP

CALIBRATION MENU LOOP

4‐24 Operation

MN2408

Page 64
Image 64
Baldor GLC25 Program Menus, Battery Voltage/Engine Speed, Tachometer, Engine Temperature/Oil Pressure, Read Only Mode