Figure 4‐18 Analog Fault Menu Loop Parameters

Fault Name

Input Analog

Fault

Setpoint Level

Setpoint Level

Action

Alarm Latch

Bypass On

Transient

 

Type

E=Enable

(Pick-up)

(Drop-out)

S=Shutdown

Y=Yes

Start

Delay (Sec)

 

 

D=Disable

 

A=Alarm

N=No

Y=Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

N=No

 

 

 

 

 

 

 

 

 

 

Under Voltage

AC Voltage

E*

 

 

S

Y

Y*

5.0

Under Frequency

AC Frequency

E*

 

 

S

Y

Y*

5.0

Weak Battery

DC Voltage

E*

18.0

N/A

A*

Y

N*

3.0

Low Battery

DC Voltage

E*

25.6

N/A

A*

N

N*

120.0

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Battery

DC Voltage

E*

30.4

N/A

A*

N

N*

10.0

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Engine Temp

Temp Sender

E*

95 °F

N/A

A*

Y

N*

5.0

High ENG Temp #1

Temp Sender

E*

198 °F

N/A

A

Y

Y

2.0

Alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High ENG Temp #2

Temp Sender

E*

206 °F

N/A

S

Y

Y

2.0

Shutdown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Oil Press #1

Press Sender

E*

30PSI

N/A

A

Y

Y*

2.0

Alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Oil Press #2

Press Sender

E*

20PSI

N/A

S

Y

Y*

2.0

Shutdown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Indicates parameter is non-programmable.

Figure 4‐19 Digital Fault Menu Loop Parameters

Fault Name

Input #

Action

Alarm Latch

Polarity

Bypass On

Transient

 

 

S=Shutdown

Y=Yes

O=Open

Start

Delay (Sec)

 

 

A=Alarm

N=No

C=Close

Y=Yes

 

 

 

 

 

 

N=No

 

 

 

 

 

 

 

 

Low Oil Pressure

1

S

-

O

Y

0.5

High ENG TEMP

2

S

-

O

Y

1.0

Batt Chgr Input Fail

3

A

Y

C

N

30.0

Low Fuel Level

4

A

N

C

N

0.1

 

 

Figure 4‐20 Calibration Menu Loop Parameters

Parameter

Setting

 

 

Volts A-B

Zero XXX

XXXVAC

 

Volts A-B

Span XXX

XXXVAC

 

Volts B-C

Zero XXX

XXXVAC

 

Volts B-C

Span XXX

XXXVAC

 

Volts C-A

Zero XXX

XXXVAC

 

Volts C-A

Span XXX

XXXVAC

 

Volts A-N

Zero XXX

XXXVAC

 

Volts A-N

Zero XXX

XXXVAC

 

Volts B-N

Zero XXX

XXXVAC

 

Volts B-N

Zero XXX

XXXVAC

 

Volts C-N

Zero XXX

XXXVAC

 

Volts C-N

Zero XXX

XXXVAC

 

Current A

Zero XXX

XXXAAC

 

Current A

Span XXX

XXXAAC

 

Current B

Zero XXX

XXXAAC

 

Current B

Span XXX

XXXAAC

 

Current C

Zero XXX

XXXAAC

 

Current C

Span XXX

XXXAAC

 

Battery Voltage

Span XXX

XX.X VDC

 

Engine Temperature

XXX

XXX C/F

 

Oil Pressure

XXX

XXXX PSI/KPA

 

4‐32 Operation

MN2408

Page 72
Image 72