Log Messages
The Syslog log messages are classified into the following 5 categories. Classification details are dealt with in the UNIX syslog and the levels are explained in Chapter 3 (→P.58).
Classification | Level | Fault Severity |
crit | Error | Critical fault at the software level (stops task operation) |
|
|
|
err | Error | Fault involving a malfunction (operation interrupted) |
|
|
|
warning | Warning | Fault not involving malfunction |
|
|
|
notice | Warning | Fault outside the system |
|
|
|
info | Information | Information on correct operation |
|
|
|
* The syslog facility is local7.
Log Messages for Applications
●A002 Protocol initialization failure (err)
Message | %1 protocol not installed |
|
|
%1 | protocol type <LS/CLS/DLS/H> |
|
|
Explanation | Webview initialization failed. |
| The settings may be corrupted. |
|
|
Response | Correct the settings or restore the factory default settings. |
|
|
146
●A004 Fault in initial video input systems settings (warning)
Message | initial video input %1 marked inactive |
|
|
%1 | Camera number |
|
|
Explanation | Because there was no input for the initial video input system, |
| VB101 has switched to automatic detection mode. The settings may be corrupted. |
|
|
Response | Correct the settings or restore the factory default settings. |
|
|
●A005 Camera control channel assignment error (warning)
Message | conflicting channel assignment for %1:%2 |
|
|
%1 | Camera control port (CC1CC2) |
|
|
%2 | Cascade Number |
|
|
Explanation | The same camera control port is assigned to multiple video input channels. |
| The settings may be corrupted. |
|
|
Response | Correct the settings or restore the factory default settings. |
|
|
●A006 Camera control system initialization failure (err)
Message | cannot open camera control port %1 |
|
|
%1 | Camera control port (CC1CC2) |
|
|
Explanation | The camera control port cannot be opened. |
|
|
Response | If rebooting does not recover this problem, there is a malfunction. Contact an authorized Canon service representative. |
|
|