3-17
Cisco BTS 10200 Softswitch Operations and Maintenance Guide, Release 6.0.x
OL-16000-07
Chapter 3 Monitoring and Backing Up the BTS
Exporting Provisioned Data
The result should match the following:
All tables are OK.
For detail, see ain_tiat.out
Caution If the result is not“All tables are OK”, stop and contact Cisco TAC.
From CA/FS Side B
Step 1 Log in as root.
Step 2 Enter:
<hostname>#cd /opt/OptiCall/CAxxx/bin
<hostname>#ca_tiat data
Step 3 Press Enter.
The result should match the following:
All tables are OK.
For detail, see ca_tiat.out
Caution If the result is not“All tables are OK”, stop and contact Cisco TAC. If the result is “All tables
are OK”, go to Step 3.
Step 4 Enter:
<hostname>#cd /opt/OptiCall/FSPTCzzz/bin
<hostname>#potsctx_tiat data
Step 5 Press Enter:
The result match the following:
All tables are OK.
For detail, see potsctx_tiat.out
Caution If the result is not“All tables are OK”, stop and contact Cisco TAC. If the result is “All tables
are OK”, go to Step 6.
Step 6 Enter:
<hostname>#cd /opt/OptiCall/FSAINyyy/bin
<hostname>#ain_tiat data
Step 7 Press Enter:
The result should match the following:
All tables are OK.
For detail, see ain_tiat.out