Chapter 3 Monitoring and Backing Up the BTS

Exporting Provisioned Data

Full Database Auditing

Step 1 Log in as CLI user on EMS side A.

Step 2 Enter audit database type=full;.

Step 3 Check the audit report and verify that there is no mismatch or error. If errors are found, try to correct the errors. If you cannot make the correction, contact Cisco TAC.

Checking Shared Memory

This task checks shared memory to detect potential data problems.

From CA/FS Side A

Step 1

Log in as root.

Step 2

Enter:

 

 

 

<hostname># cd /opt/OptiCall/CAxxx/bin

 

<hostname># ca_tiat data

 

Press Enter.

 

The result should match the following:

 

All tables are OK.

 

For details, see ca_tiat.out

 

 

 

 

 

 

Caution

 

If the result is not“All tables are OK”, stop and contact Cisco TAC. If the result is “All tables

 

 

 

 

are OK”, go to Step 3.

Step 3

Enter:

 

 

 

 

 

<hostname># cd /opt/OptiCall/FSPTCzzz/bin <Return>

 

<hostname># potsctx_tiat data <Return>

 

Press Enter.

 

The result should match the following:

 

All tables are OK.

 

For detail, see potsctx_tiat.out

 

 

 

 

 

 

Caution

 

If the result is not“All tables are OK”, stop and contact Cisco TAC. If the result is “All tables

 

 

 

 

are OK”, go to Step 4.

Step 4

Enter:

 

 

 

 

 

<hostname>#cd /opt/OptiCall/FSAINyyy/bin

 

<hostname>#ain_tiat data

Step 5

Press Enter.

 

Cisco BTS 10200 Softswitch Operations and Maintenance Guide, Release 6.0.x

3-16

OL-16000-07

Page 48
Image 48
Cisco Systems 10200 manual Full Database Auditing, Checking Shared Memory, From CA/FS Side a