Appendix A Feature Tones

Tone Frequencies and Cadences

Table A-1

Feature Tones (continued)

 

 

 

 

 

Feature

 

Tone

Condition(s) That Initiate Tone1

SC1D-ACT

 

STUTTER TONE

Stutter tone is used once after the subscriber enters the *74 (SC1D

SC2D-ACT

 

 

activation) or *75 (SC2D activation) to begin the process of collecting

 

 

the information required to provision one of the speed call slots. After a

 

 

 

 

 

 

speed call slot has been successfully provisioned, the subscriber will

 

 

 

again receive the stutter tone to signify that the speed call slot was

 

 

 

successfully provisioned.

 

 

 

 

VMWI 3

 

STUTTER TONE

The subscriber has VMWI and has a message waiting, but the serving

 

 

 

MGW does not have a visual indicator.

 

 

 

 

1.When more than one condition is listed for a single tone, any one of the conditions can cause the tone to be played.

2.For more information on the screening list, refer to the Cisco BTS 10200 Softswitch System Description.

3.MWI = message waiting indicator; VMWI = visual message waiting indicator.

Tone Frequencies and Cadences

Tones are requested by the BTS and delivered to the subscriber or operator by the MGW. Some MGWs can be provisioned to play tone cadences different than the ones described in this table.

Table A-2

Subscriber and Operator Tone Descriptions

 

 

 

 

 

 

 

Tone

 

Frequency (Hz)

Cadence Played by MGW

 

 

 

 

 

Alerting pattern (ringing) 1

440 + 480

2 sec on, 4 sec off, repeating

 

 

 

 

 

Alerting pattern (ringing) 2

440 + 480

0.8 sec on, 0.4 sec off, 0.8 sec on, 4.0 sec off, repeating

 

 

 

 

 

Alerting pattern (ringing) 3

440 + 480

0.4 sec on, 0.2 sec off, 0.4 sec on, 0.2 sec off, 0.8 sec on, 4 seconds

 

 

 

 

 

 

off, repeating

 

 

 

 

 

Alerting pattern (ringing) 4

440 + 480

0.3 sec on, 0.2 sec off, 1 sec on, 0.2 sec off, 0.3 sec on, 4 sec

 

 

 

 

 

 

off, repeating

 

 

 

 

 

Alerting pattern (ringing) 5

440 + 480

0.5 sec on once

 

 

 

 

 

Alerting pattern (ringing) 6

440 + 480

1 sec on, 3sec off, repeating

 

 

 

 

 

Busy verification

440

2 sec burst, followed by 0.5 sec burst every 10 sec

 

(used for operator BLV 1)

 

 

 

 

CW tone

 

440

0.3 sec on once

 

 

 

 

 

 

CW Type 1

 

440

0.3 sec on once

 

 

 

 

 

 

CW Type 2

 

440

0.1 sec on, 0.1 sec off, 2 times

 

 

 

 

 

 

CW Type 3

 

440

0.1 sec on, 0.1 sec off, 3 times

 

 

 

 

 

 

CW Type 4

 

440

0.1 sec on, 0.1 sec off, 0.3 sec on, 0.1 sec off, 0.1 sec on

 

 

 

 

 

Confirmation tone

350 + 440

0.1 sec on, 0.1 sec off, 3 times

 

 

 

 

 

 

Dial tone

 

350 + 440

steady on

 

 

 

 

 

Line busy tone

480 + 620

0.5 sec on, 0.5 sec off, repeating

 

 

 

 

 

Message waiting indicator tone

350 + 440

10 bursts (0.1 sec on, 0.1 sec off), then steady on

 

 

 

 

 

Off-hook warning tone

1400 + 2060 +

0.1 sec on, 0.1 sec off, repeating

 

(receiver off-hook tone)

2450 + 2600

 

 

 

 

 

 

 

 

 

 

 

 

 

 