Chapter 4 Operating the BTS

Using Status and Control Commands

Table 4-3 Using Status and Control Commands (continued)

Task

Sample Command

 

 

 

 

Changing states of

control call-agent id=CA146; target-state=FORCED-STANDBY-ACTIVE;

 

component pairs

Possible states:

 

(EMS, BDMS, CA,

 

 

 

 

 

 

 

and FS)

 

ACTIVE_STANDBY

 

 

 

STANDBY_ACTIVE

 

 

 

NORMAL—Primary is active and secondary is standby.

 

 

 

FORCED-ACTIVE-STANDBY—Primary has been forced to active and

 

 

 

 

secondary is standby.

 

 

 

FORCED-STANDBY-ACTIVE—Primary has been forced to standby and

 

 

 

 

secondary is active.

 

 

 

 

Viewing component

status application id=CA146;

 

application states

 

 

 

 

 

 

 

 

 

Changing

control application id=CA146; action=star;node=prica06

 

component

 

 

 

 

 

 

applications states

 

 

 

 

 

 

Caution This negatively impacts the performance of the BTS host.

 

(in-service or OOS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Activating media

Ensure the MG exists, then enter:

 

gateways

control mgw id=<mgw-id>; target-state=ins; mode=forced;

 

 

 

 

where

 

 

 

mgw id—the voice port on the subscriber’s MTA (the voice port’s MAC

 

 

 

 

address without hyphens)

 

 

 

target-state—ins to show in service for all activations

 

 

 

mode—forced for all activations

 

 

 

 

Setting subsystem

control subsystem_grp id=CNAM; mode=forced; target_state=UOS;

 

groups/OPC in or

This sets the state of the individual subsystems within the subsystem group as

 

OOS

 

well. If a subsystem/OPC combination is taken OOS individually, the state of

 

 

 

 

the subsystem group may be in service while some members of the group are

 

 

out of service.

 

 

 

 

Viewing subsystem

status subsystem_grp id=CNAM

 

groups/OPC status

 

 

 

 

 

 

 

 

 

 

 

 

 

Cisco BTS 10200 Softswitch Operations and Maintenance Guide, Release 6.0.x

4-8

OL-16000-07

 

 

Page 70