Manuals
/
Dell
/
Household Appliance
/
Plumbing Product
Dell
EMU01
owner manual
Dell PowerEdge 6950 Systems
Models:
EMU01
1
1
166
166
Download
166 pages
63.99 Kb
1
2
3
4
5
6
7
8
Troubleshooting
Install
Error messages
Password
E1810 HDD ## Fault
E2017 Timer Fail
Hard-Drive Indicator Codes
Connecting External Devices
Configuration, Resource
Checking Basic Power Problems
Page 1
Image 1
Dell™ PowerEdge™ 6950 Systems
Hardware Owner’s Manual
w w w . d e l l . c o m s u p p o r t . d e l l . c o m
Page 1
Page 2
Page 1
Image 1
Page 1
Page 2
Contents
W . d e l l . c o m s u p p o r t . d e l l . c o m
Dell PowerEdge 6950 Systems
September PM296
Contents
Expansion Card Installation Guidelines
Baseboard Management Controller Configuration
General Memory Module Installation Guidelines
Removing and Replacing the Optional Front Bezel
Connecting an External Fibre Channel Storage Device
Installing the SAS RAID Controller Card Battery
Control Panel Assembly Service-Only Procedure
Fan Interposer Board Service-Only Procedure
100
Troubleshooting System Cooling Problems 105
101
102
109
Troubleshooting an External SAS Tape Drive 112
110
111
Dell Enterprise Training and Certification 131
Returning Items for Warranty Repair or Credit 131
132
134
About Your System
Other Information You May Need
Accessing System Features During Startup
Front-Panel Features and Indicators
USB connectors
System temperature, or hard drives
Messages
Both the systems management software
Amber
Hard-Drive Indicator Codes
Connecting External Devices
Back-Panel Features and Indicators
Expansion-card slots Power supply System status indicator
Optional
Power Indicator Codes
LCD Status Messages
NIC Indicator Codes
Support E1A14 SAS Cable a
E1000 FAILSAFE, Call
E1A15 SAS Cable B
E1114 Temp Ambient
Voltage
E122B 9V Over
E122D
E122E
E1418 CPU # Presence
E1414 CPU # Thermtrip
E1423
Missing
E1610 PS # Missing
E1422 CPU Machine Chk
E1614 PS # Status
E1618 PS # Predictive
E2011 Mem Config Err
E1810 HDD ## Fault
E1712
PCI Serr Slot #
E2017 Timer Fail
E2013 Shadow Bios Fail
E2018 Prog Timer
E2019 Parity Error
Solving Problems Described by LCD Status Messages
Removing LCD Status Messages
System Messages
Remote Configuration
Attempting to update
Please wait Bios Update Attempt
Is installed on system
Manufacturing mode
Configuration, Resource
No boot device available
Gate A20 failure
No timer tick interrupt
No boot sector on hard
Not a boot diskette
Error Embedded
Remote Access Controller
Read fault
Not installed in the RAC
Seek error
Timer chip counter
Please run Setup program
DIMMs are disabled
Update loaded for
Write fault
Diagnostics Messages
Write fault on selected
Alert Messages
Responding to Error Messages
Entering the System Setup Program
Using the System Setup Program
Using the System Setup Program
System Setup Program Navigation Keys Action Enter
System Setup Options
Main Screen
Submenu, such as Memory Information
CPU Information Screen on
Boot Sequence Retry
System Setup Program Options Description Boot Sequence
To boot after 30 seconds
Using the Setup Password on page 40 for more information
CPU Information Screen
Memory Information Screen
Integrated Devices Screen
System Security Screen
Using the System Password
System and Setup Password Features
Last default
Restored
Using the System Setup Program
Using the Setup Password
Baseboard Management Controller Configuration
Disabling a Forgotten Password
See Disabling a Forgotten Password on
BMC Setup Module Options
Entering the BMC Setup Module
Installing System Components
Installing System Components
Inside the System
Recommended Tools
Expansion cards SAS controller card Optional RAC
Removing and Replacing the Optional Front Bezel
Drives
Opening the System
Opening and Closing the System
Closing the System
Cooling Fans
Fan-bay power connector
Removing a Cooling Fan
Replacing a Cooling Fan
Cooling Shrouds
Removing the Cooling Shrouds
Three cooling shrouds direct airflow within the system
Top cooling shroud Guide Slot
Replacing the Cooling Shrouds
Removing a Power Supply
Power Supplies
Expansion Card Installation Guidelines
Replacing a Power Supply
Expansion Cards
Installing an Expansion Card
Installing System Components
Expansion card
Removing an Expansion Card
Cards only
RAC Card
System Memory
Connector
General Memory Module Installation Guidelines
Memory
Two-Processor Memory Configurations Total
Ejectors Installing System Components
Installing Memory Modules
Removing Memory Modules
Removing a Processor
Processors
11. Removing and Installing the Heat Sink Heat sink
New processor Socket Processor shield Socket keys
Installing a Processor
Installing System Components
Processor VRMs
Installing a VRM
Socket ejectors
Removing a VRM
Installing a Diskette Drive
15. Installing a Diskette Drive in the Drive Carrier
Installing an Optical Drive
Plastic rivets Latch Thumbscrew
Optical drive
Hard Drives
Configuring the Boot Device
Before You Begin
Removing a Drive Blank
Installing a Drive Blank
Removing a Hot-Plug Hard Drive
Installing a Hot-Plug Hard Drive
Replacing a Hard Drive in a Hard-Drive Carrier
Installing the SAS RAID Controller Card Battery
Installing a SAS Controller Card
SAS Controller Cards
Removing a SAS Controller Card
Connecting an External SAS Tape Drive
System Battery
Connecting an External Fibre Channel Storage Device
Replacing the System Battery
System battery is a 3.0-volt V, coin-cell battery
Connector Installing System Components
Removing the Control Panel
Control Panel Assembly Service-Only Procedure
Display module Display module cable
Installing the Control Panel
Control panel board cable
Removing a Fan Interposer Board
Fan Interposer Board Service-Only Procedure
Slots
Installing a Fan Interposer Board
Removing the Power Distribution Board
Power Distribution Board Service-Only Procedure
Installing the Power Distribution Board
Removing the Chassis Intrusion Switch
Chassis Intrusion Switch Service-Only Procedure
Intrusion-switch cable Installing System Components
Installing the Chassis Intrusion Switch
SAS Backplane Service-Only Procedure
Removing the SAS Backplane
Retention slots Installing System Components
Installing the SAS Backplane
System Board Service-Only Procedure
Removing the System Board
Slide switches
Harness
Lift the system board out of the chassis, left side first
Remove the system board
Installing the System Board
Installing System Components
Installing System Components
Installing System Components
Software Monitors power indicator
Safety First-For You and Your System
Start-Up Routine
Start-Up Routine Indications Look/listen for Action
Troubleshooting IRQ Assignment Conflicts
Checking Basic Power Problems
Checking the Equipment
Troubleshooting the Video Subsystem
Troubleshooting External Connections
Monitor is not working properly Video memory is faulty
Troubleshooting the Mouse
Troubleshooting the Keyboard
Troubleshooting a Serial I/O Device
Troubleshooting Serial I/O Problems
Troubleshooting a USB Device
101
NIC cannot communicate with network
Troubleshooting a NIC
Troubleshooting a Damaged System
Troubleshooting a Wet System
Liquid spilled on the system Excessive humidity
System was dropped or damaged
Troubleshooting the System Battery
Troubleshooting System Cooling Problems
Troubleshooting Power Supplies
105
Troubleshooting a Fan
Troubleshooting System Memory
107
Error message indicates a diskette drive problem
Troubleshooting a Diskette Drive
109
Troubleshooting an Optical Drive
Troubleshooting a Hard Drive
111
Troubleshooting a SAS Controller or SAS RAID Controller
Troubleshooting an External SAS Tape Drive
113
Troubleshooting Expansion Cards
Troubleshooting the Microprocessors
115
116
System Diagnostics Features
Using Dell PowerEdge Diagnostics
Running the System Diagnostics
117
Running the System Diagnostics
When to Use the System Diagnostics
System Diagnostics Testing Options
Using the Custom Test Options
Selecting Diagnostics Options
Selecting Devices for Testing
Viewing Information and Results
119
120
System Board Jumpers
Jumpers and Connectors
121
Pswden Nvramclr
123
124
System Board Connectors
125
Connector for the 3.0-V coin battery
Processor 2 connector
Control panel cable connector
126
Data interface Power Control panel on front
SAS Backplane Board Connectors
Board Jumpers and Connectors
127
128
Technical Assistance
Online Services
129
Getting Help
Automated Order-Status Service
AutoTech Service
Technical Support Service
Electronic Quote Service
131
132
Before You Call
133
134
Contacting Dell
Mail la-techsupport@dell.com General Support Toll-free
Mail la-techsupport@dell.com General Support
135
Technical Support Services
Technical Support
Sales
General Support Toll-free
136
137
Mail la-techsupport@dell.com General Support 01-800-915-4755
138
General Support calling from Guayaquil
139
3355
Mail la-techsupport@dell.com General Support 800-6132
140
141
142
143
144
Mail krsupport@dell.com
145
146
147
Fax 21 424 01
148
149
150
Technical Support OptiPlex, Latitude, Inspiron
151
152
International Access Code Country Code City Code
Mail delldirectsupport@dell.com Customer Care website
Home and Small Business Fax 0870 907
153
154
Amperes AC Alternating current
155
BTU British thermal unit
Celsius
CPU Central processing unit. See processor DC Direct current
156
Fahrenheit
157
FBD Fully buffered Dimm
Kilo Kb Kilobits 1024 bits Glossary
LVD Low voltage differential Meters MA Milliamperes
158
Romb RAID on motherboard Rpm Revolutions per minute Glossary
159
TCP/IP Transmission Control Protocol/Internet Protocol
160
Volts VAC Volts alternating current VDC Volts direct current
161
162
Index
163
Microprocessor See processor
165
Index
Top
Page
Image
Contents