Power Supplies

Your system supports two power supplies rated at an output of 1570 W. The second power supply serves as a redundant, hot-plug power source.

NOTICE: The system is only in the redundant mode when two power supplies are installed and both power supplies are connected to an AC power source. If some third-party components (such as PCI cards) not tested or supported by Dell are installed, the power supplies may not be redundant at all input voltages.

NOTICE: Operating the system with only one power supply installed for extended periods of time can cause the system to overheat.

Removing a Power Supply

1Disconnect the power cable from the power source and the power supply you intend to remove.

2Press the lever release latch, then open the release lever and slide the power supply out of the chassis. See Figure 3-6.

NOTE: You may have to unlatch and lift the cable management arm if it interferes with power-supply removal. For information about the cable management arm, see the system’s Rack Installation Guide.

Figure 3-6. Removing and Replacing a Power Supply

1

2

 

3

1 power supply

2

release lever

3

lever release latch