22 About Your System
E2013 Shadow BIOS Fail The system BIOS failed to copy
its flash image into memory.
See "Troubleshooting System
Memory" on page106.
E2014 CMOS Fail CMOS failure. CMOS RAM not
functioning properly.
See "Getting Help" on page129.
E2015 DMA Controller DMA controller failure. See "Getting Help" on page129.
E2016 Int Controller Interrupt controller failure. See "Getting Help" on page129.
E2017 Timer Fail Timer refresh failure. See "Getting Help" on page129.
E2018 Prog Timer Programmable interval timer
error.
See "Getting Help" on page129.
E2019 Parity Error Parity error. See "Getting Help" on page129.
E201A SIO Err SIO failure. See "Getting Help" on page 129.
E201B Kybd Controller Keyboard controller failure. See "Getting Help" on page129.
E201C SMI Init System management interrupt
(SMI) initialization failure.
See "Getting Help" on page129.
E201D Shutdown Test BIOS shutdown test failure. See "Getting Help" on page129.
E201E POST Mem Test BIOS POST memory test failure. See "Troubleshooting System
Memory" on page106. If problem
persists, see "Getting Help" on
page129.
E201F DRAC Config Dell remote access controller
(DRAC) configuration failure.
Check screen for specific error
messages.
Ensure that the DRAC card and
cables are properly seated. See
"RAC Card" on page56. If
problem persists, see your DRAC
documentation.
E2020 CPU Config CPU configuration failure. Check screen for specific error
messages.
E2021 Memory
Population Incorrect memory configuration.
Memory population order
incorrect.
Check screen for specific error
messages. See "Troubleshooting
System Memory" on page106.
E2022 POST Fail General failure after video. Check screen for specific error
messages.
Table 1-7. LCD Status Messages (continued)
Line 1
Message
Line 2
Message
Causes Corrective Actions