Table 1-7. LCD Status Messages

Line 1

Line 2

Causes

Corrective Actions

Message

Message

 

 

 

 

 

 

N/A

SYSTEM NAME

A 62-character string that can be

This message is for information

 

 

defined by the user in the System

only.

 

 

Setup program.

You can change the system string

 

 

 

 

 

The SYSTEM NAME displays

in the System Setup program. See

 

 

under the following conditions:

"Using the System Setup

 

 

• The system is powered on.

Program" on page 31.

 

 

• The power is off and active

 

 

 

POST errors are displayed.

 

 

 

 

 

E1000

FAILSAFE, Call

 

See "Getting Help" on page 129.

 

Support

 

 

 

 

 

 

E1A14

SAS Cable A

SAS cable A is unseated, missing,

Check the cable connection to

 

 

or bad.

the SAS backplane. See "SAS

 

 

 

Backplane Board Connectors" on

 

 

 

page 127.

E1A15

SAS Cable B

SAS cable B is unseated, missing,

 

 

or bad.

Check the cable connection to the SAS backplane. See "SAS Backplane Board Connectors" on page 127.

E1114

Temp Ambient

Ambient system temperature is

See "Troubleshooting System

 

 

out of acceptable range.

Cooling Problems" on page 105.

 

 

 

 

E1210

CMOS Batt

CMOS battery is missing, or the

See "Troubleshooting the System

 

 

voltage is out of acceptable range.

Battery" on page 104.

 

 

 

 

E1211

ROMB Batt

RAID battery is either missing,

Reseat the RAID battery. See

 

 

bad, or unable to recharge due to

"Installing the SAS RAID

 

 

thermal issues.

Controller Card Battery" on

 

 

 

page 76, and "Troubleshooting

 

 

 

System Cooling Problems" on

 

 

 

page 105.

 

 

 

 

E12nn

XX PwrGd

Specified voltage regulator has

See "Getting Help" on page 129.

 

 

failed.

 

 

 

 

 

E1229

CPU # VCORE

Processor # VCORE voltage

See "Getting Help" on page 129.

 

 

regulator has failed.

 

 

 

 

 

E122A

CPU # VTT

Processor # VTT voltage has

See "Getting Help" on page 129.

 

 

exceeded the allowable voltage

 

 

 

range

 