Table
Line 1 | Line 2 | Causes | Corrective Actions |
Message | Message |
|
|
|
|
|
|
N/A | SYSTEM NAME | A | This message is for information |
|
| defined by the user in the System | only. |
|
| Setup program. | You can change the system string |
|
|
| |
|
| The SYSTEM NAME displays | in the System Setup program. See |
|
| under the following conditions: | "Using the System Setup |
|
| • The system is powered on. | Program" on page 31. |
|
| • The power is off and active |
|
|
| POST errors are displayed. |
|
|
|
|
|
E1000 | FAILSAFE, Call |
| See "Getting Help" on page 129. |
| Support |
|
|
|
|
|
|
E1A14 | SAS Cable A | SAS cable A is unseated, missing, | Check the cable connection to |
|
| or bad. | the SAS backplane. See "SAS |
|
|
| Backplane Board Connectors" on |
|
|
| page 127. |
E1A15 | SAS Cable B | SAS cable B is unseated, missing, |
|
| or bad. |
Check the cable connection to the SAS backplane. See "SAS Backplane Board Connectors" on page 127.
E1114 | Temp Ambient | Ambient system temperature is | See "Troubleshooting System |
|
| out of acceptable range. | Cooling Problems" on page 105. |
|
|
|
|
E1210 | CMOS Batt | CMOS battery is missing, or the | See "Troubleshooting the System |
|
| voltage is out of acceptable range. | Battery" on page 104. |
|
|
|
|
E1211 | ROMB Batt | RAID battery is either missing, | Reseat the RAID battery. See |
|
| bad, or unable to recharge due to | "Installing the SAS RAID |
|
| thermal issues. | Controller Card Battery" on |
|
|
| page 76, and "Troubleshooting |
|
|
| System Cooling Problems" on |
|
|
| page 105. |
|
|
|
|
E12nn | XX PwrGd | Specified voltage regulator has | See "Getting Help" on page 129. |
|
| failed. |
|
|
|
|
|
E1229 | CPU # VCORE | Processor # VCORE voltage | See "Getting Help" on page 129. |
|
| regulator has failed. |
|
|
|
|
|
E122A | CPU # VTT | Processor # VTT voltage has | See "Getting Help" on page 129. |
|
| exceeded the allowable voltage |
|
|
| range |
|
About Your System