Table 1-8. System Messages (continued)

Message

 

Causes

Corrective Actions

 

 

 

 

This system

supports only

Microprocessor(s) is not supported by

Install a supported microprocessor or

Opteron 8000 series

the system.

microprocessor combination. See

processors.

 

 

"Installing a Processor" on page 64.

 

 

 

 

Time-of-day

clock stopped

Faulty battery or faulty chip.

See "Troubleshooting the System

 

 

 

Battery" on page 104.

Time-of-day not set -

Incorrect Time or Date settings; faulty

please run SETUP program

system battery.

Check the Time and Date settings. See "Using the System Setup Program" on page 31. If the problem persists, replace the system battery. See "System Battery" on page 78.

Timer chip counter 2

Faulty system board.

See "Getting Help" on page 129.

failed

 

 

Unsupported CPU

Microprocessor(s) is not supported by

combination

the system.

Unsupported CPU stepping

 

detected

 

Install a supported microprocessor or microprocessor combination. See "Installing a Processor" on page 64.

Utility partition not

The <F10> key was pressed during

Create a utility partition on the boot

available

POST, but no utility partition exists

hard drive. See the CDs that came with

 

on the boot hard drive.

your system.

 

 

 

Warning: Following faulty

Faulty or improperly seated memory

See "Troubleshooting System Memory"

DIMMs are disabled:

module(s) used by CPUn.

on page 106.

CPUn: DIMM n

 

 

CPUn: DIMM n

 

 

Total memory size is

 

 

reduced.

 

 

 

 

 

Warning! No microcode

Microcode update failed.

Update the BIOS firmware. See "Getting

update loaded for

 

Help" on page 129.

processor n

 

 

 

 

 

Warning: One or more

Faulty or improperly seated memory

See "Troubleshooting System Memory"

faulty DIMMs found on CPUn

module(s) used by CPUn.

on page 106.

 

 

 

Warning: The installed

Invalid memory configuration. The

Ensure that the memory modules are

memory configuration is

system will run but with reduced

installed in a valid configuration. See

not optimal. For more

functionality.

"General Memory Module Installation

information on valid

 

Guidelines" on page 58. If the problem

memory configurations,

 

persists, see "Troubleshooting System

please see the system

 

Memory" on page 106.

documentation on the

 

 

technical support web

 

 

site.

 

 