Table
Message |
| Causes | Corrective Actions |
|
|
|
|
This system | supports only | Microprocessor(s) is not supported by | Install a supported microprocessor or |
Opteron 8000 series | the system. | microprocessor combination. See | |
processors. |
|
| "Installing a Processor" on page 64. |
|
|
|
|
| clock stopped | Faulty battery or faulty chip. | See "Troubleshooting the System |
|
|
| Battery" on page 104. |
| Incorrect Time or Date settings; faulty |
please run SETUP program | system battery. |
Check the Time and Date settings. See "Using the System Setup Program" on page 31. If the problem persists, replace the system battery. See "System Battery" on page 78.
Timer chip counter 2 | Faulty system board. | See "Getting Help" on page 129. |
failed |
|
|
Unsupported CPU | Microprocessor(s) is not supported by |
combination | the system. |
Unsupported CPU stepping |
|
detected |
|
Install a supported microprocessor or microprocessor combination. See "Installing a Processor" on page 64.
Utility partition not | The <F10> key was pressed during | Create a utility partition on the boot |
available | POST, but no utility partition exists | hard drive. See the CDs that came with |
| on the boot hard drive. | your system. |
|
|
|
Warning: Following faulty | Faulty or improperly seated memory | See "Troubleshooting System Memory" |
DIMMs are disabled: | module(s) used by CPUn. | on page 106. |
CPUn: DIMM n |
|
|
CPUn: DIMM n |
|
|
Total memory size is |
|
|
reduced. |
|
|
|
|
|
Warning! No microcode | Microcode update failed. | Update the BIOS firmware. See "Getting |
update loaded for |
| Help" on page 129. |
processor n |
|
|
|
|
|
Warning: One or more | Faulty or improperly seated memory | See "Troubleshooting System Memory" |
faulty DIMMs found on CPUn | module(s) used by CPUn. | on page 106. |
|
|
|
Warning: The installed | Invalid memory configuration. The | Ensure that the memory modules are |
memory configuration is | system will run but with reduced | installed in a valid configuration. See |
not optimal. For more | functionality. | "General Memory Module Installation |
information on valid |
| Guidelines" on page 58. If the problem |
memory configurations, |
| persists, see "Troubleshooting System |
please see the system |
| Memory" on page 106. |
documentation on the |
|
|
technical support web |
|
|
site. |
|
|
About Your System
29