Fostex D-160 owner manual 178, Signature map

Models: D-160

1 196
Download 196 pages 45.48 Kb
Page 178
Image 178

D-160 Owner's Manual (MMC/FEX List/Maintenance/Specifications)

<signature map>

bar2, bar1, bar0, sign, sigd

 

 

bar2: The 100th digit of the bar figure is expressed in BCD.

 

bar1: The 10th digit of the bar figure is expressed in BCD.

 

bar0: The 1 digit of the bar figure is expressed in BCD.

 

sign: Numerator of the signature to be set is expressed in BCD.

 

sigd: Denominator of the signature to be set is expressed in BCD.

 

When specified as sign=00 and sigd=00, signature data of that bar position will be

 

deleted. Also, bar2=bar1=bar0=sign=sigd=00 indicates "no corresponding data"

 

(such as when a figure specified by <event number> do not exist at receiving the

 

signature map request).

 

<tempo set map>

bar2, bar1, bar0, beat, tmp2, tmp1, tmp0

 

bar2: The 100th digit of the bar figure is expressed in BCD.

 

bar1: The 10th digit of the bar figure is expressed in BCD.

 

bar0: The 1 digit of the bar figure is expressed in BCD.

 

beat: The beat figure is expressed in BCD.

 

tmp2: Numerator of the tempo to be set is expressed in BCD.

 

tmp1: Denominator of the tempo to be set is expressed in BCD.

 

tmp0: The 1 digit of the tempo is expressed in BCD.

 

When specified as tmp2=tmp1=tmp0=00, tempo data of that bar and meter position

 

will be deleted. Also, bar2=bar1=bar0=sign=sigd=00 indicates "no corresponding

 

data" (such as when a figure specified by <event number> do not exist at receiving

 

the signature map request).

 

<event number>

When one data registered by <signature map> and <tempo set map> is declared as

 

one event, the number of events from head of the tune (the umpteenth event

 

counted from head of the tune) must be specified. <event number="00"> is the first

 

event.

 

<midi sync>

00: Off

 

 

01: CLK (MIDI CLOCK)

 

 

02: MTC

 

 

This corresponds to "Midi Sync Out?" of the SETUP menu.

<vari data>

Will be composed of two bytes (Q, P).

 

 

Q: 0qqqqqqq (binary) -> <vari data> = "qqqqqqqppppppp" A 14 bit data of X0.1

 

P: 0qqqqqqq (binary)

attached with a minus symbol.

 

Vari-pitch must be specified, at +0.1% when MSB (q)=0 (Example: 0000000000001),

 

and at -0.1% when MSB (q)=1 (Example: 1111111111111).

<frame rate>

00: 30nd

 

 

01: 29.97nd

 

 

02: 29.97df

 

 

03: 25

 

 

04: 24

 

 

05: 30df

 

 

Corresponds to selecting "Frame Rate?" of the SETUP menu.

<fs rate>

00: 48kHz

 

 

01: 44.1kHz

 

 

Corresponds to selecting "Sample Rate?" of the SETUP menu.

<MTC offset mode>

00: ABS

 

 

01: Signature

 

 

Corresponds to selecting "MTC Offset Mode?" of the SETUP menu.

<time base>

00: ABS

 

 

01: BAR BEAT

 

 

02: MTC

 

<level data>

t1, t2 ...... tn

 

 

n: Indicates the track number.

 

 

tn: Indicates absolute 8 bits of the Audio 16 bit data.

 

 

 

178