D-160 Owner's Manual (Saving and loading data)

2.Loading the data using DATA IN

*Restore the initial settings on the D-160.

*Set the same sampling rate on the external digital device and the D-160.

Connecting the external device

Connect DATA INPUT 1-8 connectors of the D-160 to the digital output connectors on the external digital device.

<Notes>

*The D-160 has DATA INPUT connectors for an S/P DIF digital signal (OPTICAL) and for an adat digital signal. These connectors have the same shape but carry different information.

*Use the DATA INPUT 1-8 connector to load data. Do not use the DATA INPUT 9-16 connector.

*When save/load using DAT and adat, independent save/load in 8 track units is possible. In this case, the data in 8 track units are not distinguished as track 1~8 or 9~16 but simply handled as eight track data. Therefore, as this 8 track data is compatible with D-90 if it is in 8 track units (any one combination of 1~8, 9~16 or 17~24), data saved from D-160 can be loaded in tracks 1~8 of the D-90. In this case, data in the tracks which was not loaded will remain intact.

 

CAUTION

 

RISK OF ELECTRIC SHOCK

AVIS

DO NOT OPEN

NE PAS OUVRIR

 

:RISQUE DE CHOC ELECTRIQUE

WARNING:D-160

TO REDUCE THE RISK OF FIRE OR ELECTRIC

SHOCK. DO NOT EXPOSE THIS EQUIPMENT

TO RAIN OR MOISTURE.

 

ANALOG IN

 

 

 

 

ANALOG OUT

 

 

 

 

DATA

OPTICAL

SCSI

 

MIDI

 

4

3

2

1

8

7

6

5

4

3

2

1

INPUT

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9~16

1~8

9~6

1~8

INPUT

OUTPUT

THRU

8

7

6

5

16

15

14

13

12

11

10

9

 

 

 

 

 

 

 

DATA INPUT 1-8

DIGITAL OUT

External Digital Equipment (DAT or RD-8 or Adat)

If the external device has only COAXIAL type (RCA) digital I/O connectors, connect an optional COP-1 (optical/coaxial converter) to use an S/P DIF digital signal.

Connecting both output and input connectors on the D-160 to the input and output connectors on the external digital device respectively may generate a digital loop. Refer to “4-3. Connecting a digital mixer” on page "65" for more information.

Setting up an external device

1.Setup the external device so that it can output a digital signal.

2.Locate the beginning of the pilot signal recorded in the saved data.

*Refer to the instruction manual that came with your external digital device for details.

Executing the load operation

You will use the “Load PGM ?” menu in Setup mode.

*Input format available: adat, DAT, SCSI

*Programs available: P1 - P99

*You can load one saved Program at a time.

1.Press the DISP SEL key to select “SETUP” (“SETUP” will flash) and press the EXECUTE/YES key. (“SETUP” will light up.)

The D-160 will enter the Setup mode.

2.Use the JOG dial to select “Load PGM ?” (“?” will flash.).

3.Press the EXECUTE/YES key.

The message “Load Device?” and the type of digital signal to be loaded (“DAT,” “adat,” or “SCSI”) will flash on the display.

106

Page 106
Image 106
Fostex D-160 owner manual Loading the data using Data, 106, Connecting the external device, Executing the load operation