GBC F - 160 CE manual Function check, Control panel

Models: F - 160 CE

1 127
Download 127 pages 9.05 Kb
Page 50
Image 50

F - 160 CE Operation and Maintenance Manual

Installation

 

 

4.11 Function check

The function check ensures that the laminator functions properly when operating. This check is recommended before performing any applications.

If a step that does not react according to the description, call your local area service representative immediately.

W A R N I N G

Do not wear ties, loose fit clothing or dangling jewelry while operating or servicing the laminator. These items can get caught in the nip and choke you or you can be crushed or burned.

4.11.1Control panel

a)Press TOP TEMP. to a value of 120oF ( 48 oC ). TOP TEMP DISPLAY begins flashing.

TOP TEMP

BOT TEMP

120 -

68

b)Press BOT TEMP to a value of 120oF ( 48 oC ). BOT TEMP DISPLAY begins flashing.

TOP TEMPBOT TEMP

120

120

-

-

c)SEL can not be tested until you have saved parameters within a JOB location. Refer to Section 5.4 Job programming for SEL and SAV.

S

L

SAV

JOB 0

STANDBY

 

= Flashing

d)Press GAP once. GAP DISPLAY decreases 1/16th of an inch per press. The upper main roller moves accordingly. Once to “0”, the upper main roller is contacting the lower main roller.

GAPPRESSURE

1-0

© GBC Films Group April 2000

Page 4 - 23

Page 50
Image 50
GBC F - 160 CE manual Function check, Control panel