Installation

F - 160 CE Operation and Maintenance Manual

 

 

c)Feed the power cable through the power cable strain relief located at the bottom of the drive side leg.

Strain relief

W A R N I N G

Follow the correct wiring diagram when

supplying power to the laminator. If

improperly connected, you can be seriously injured or cause damage to the laminator.

d)Connect the power cord to the line terminal block. Refer to Figure 4.9.1 Single phase or Figure 4.9.2 Wye three phase.

Figure 4.9.1 Single phase illustrates proper single phase wiring for the U.S. and Canada.

Figure 4.9.2 Wye three phaseillustrates proper

Wye 3 phase wiring for Europe.

e)Turn the junction box power to the ON position.

f)Verify line voltage with regards to the type of power being supplied to the laminator at the line terminal block.

Line terminal block

g)Once the power cord has been properly connected, replace the drive side leg cover.

h) Proceed with 4.10 Safety check.

Page 4 - 16

© GBC Films Group April 2000

Page 43