Operations

F - 160 CE Operation and Maintenance Manual

 

 

( 5 ) BOT. TEMP. DISPLAY : The display will show the set point temperature of the bottom main roller as the default display. When the bottom roller temperature has reached in the +/- 10oF range of the set point, the display will be solid. When outside of this range, the display will flash.

( 8 ) OVER/ UNDER INDICATORS : Dislays a “+” if the temperature is above the set point. Display a “–” if the temperature is below the set point. If neither (+/ -) is displayed, the temperaure is within the +/- 6 oF range.

TOP TEMP

BOT TEMP

68

68

5

TOP TEMPBOT TEMP

68

68

-

+

 

 

8

 

( 6 ) BOT. TEMP. : When pressed, will increase the set point value of the bottom main roller in increments of 2 degrees. If this key is held down, it will only increase to the maximum temperature setting of 290oF ( 143oC ).

( 9 ) GAP DISPLAY : Displays the current main roller nip opening. The nip has a range of 0 to 1” gap.

 

6

TOP TEMP

BOT TEMP

68

68

GAPPRESSURE

1/16

9

( 7 ) BOT. TEMP. : When pressed, will decrease the set point value of the bottom main roller in increments of 2 degrees. If held down, it will decrease to the minimum temperature setting of 68oF ( 20oC ).

( 10 ) GAP : When pressed, will increase the gap by 1/16 in. increments. If held down, it will automatically increase the gap by 1/16 in. increments until it has reached a maximum opening of 1 in. on the GAP DISPLAY.

TOP TEMP

BOT TEMP

6 8

6 8

 

7

10

GAPPRESSURE

1/16

Page 5 - 2

© GBC Films Group April 2000

Page 59
Image 59
GBC F - 160 CE manual Operations CE Operation and Maintenance Manual