GE EPM5200P, EPM9450Q, EPM 7300, EPM 7700, PMCS 6.11a, GEH-6513, EPM9650Q manual Pmcs DDE

Models: PMCS 6.11a EPM5200P EPM 7300 EPM9650Q GEH-6513 EPM9450Q EPM 7700

1 304
Download 304 pages 50.89 Kb
Page 35
Image 35

 

Annunciator Panel Wizard monitors DDE Items at Event Logger

 

 

 

Relay 1

 

Relay 2

 

Relay 3

 

DDE Item Name: Trip1

 

 

 

 

 

 

 

 

 

(green)

 

(green)

 

(green)

 

 

 

 

 

 

 

Status:

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Configured Events

 

Received

 

 

 

 

 

 

 

 

 

Relay Tripped?

 

NO

Event Logger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error Condition?

 

NO

 

 

 

 

 

 

 

 

tracks events

 

 

 

 

 

 

 

Overvoltage Condition?

NO

 

 

 

 

 

 

 

 

Annunciator Panel Wizard

 

reported by

 

 

Event Logger

 

 

 

 

 

 

 

 

 

PMCS DDE

 

 

 

 

 

 

 

 

 

 

Server

 

 

 

 

 

 

 

 

 

 

 

 

Relay 1

 

 

 

 

 

 

 

 

 

PMCS

 

 

 

 

 

 

 

 

 

 

Relay 2

 

 

 

 

 

 

 

 

 

DDE Server

 

 

 

 

 

 

 

 

 

 

 

Annunciator Panel Wizard monitors DDE Items at Event Logger

 

 

Relay 3

 

 

 

 

 

 

 

Relay 1

 

Relay 2

 

Relay 3

 

DDE Item Name: Trip1

 

 

 

 

 

 

 

 

 

(red)

 

(green)

 

(green)

 

 

 

 

 

 

 

Status:

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Configured Events

 

Received

 

 

 

 

 

 

 

 

 

Relay Tripped?

 

YES

Event Logger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error Condition?

 

NO

 

 

 

 

 

 

 

 

tracks events

 

 

 

 

 

 

 

Overvoltage Condition?

NO

 

Annunciator Panel Wizard

 

reported by

 

 

Event Logger

 

 

 

 

 

 

 

 

 

PMCS DDE

 

Server

 

 

PMCS

 

Relay 1

 

 

Relay 2

DDE Server

 

 

 

 

 

Relay 3

 

 

In the upper illustration, the Event Logger watches for any of the three events configured to cause a change of state to the Trip 1 DDE Item. None of these three events have occurred, so the status of the Trip 1 DDE Item is at OFF. The Annunciator Panel wizard is monitoring the configured DDE Items at the Event Logger, but all DDE Items are “OFF” so the Annunciator Panel displays green indicator tiles.

In the lower illustration, the Event Logger has recorded a “Trip” event for the unit in question, and changed the state of the Trip 1 DDE Item to “ON”. The Annunciator Panel wizard sees this change, and responds by changing the color of the annunciator panel tile for Relay 1 to red.

27

Page 35
Image 35