Before you call for service…

TroubleshootingTips

Savetimeandmoney!Reviewthechartsonthefollowingpages, orvisitGEAppliances.com.Youmaynotneedtocallforservice.

PROBLEM

Possible Causes

What To Do

 

 

 

Dryer shakes or

Some shaking/noise is normal.

• Move dryer to an even floor space, or adjust leveling legs

makes noise

Dryer may be sitting unevenly

as necessary until even.

 

 

 

Clothes take too long

Improper or obstructed ducting

• Check the Installation Instructions to make sure the

to dry

 

dryer venting is correct.

 

 

• Make sure ducting is clean, free of kinks and

 

 

unobstructed.

 

 

• Check to see if outside wall damper operates easily.

 

 

 

 

Improper sorting

• Separate heavy items from lightweight items (generally,

 

 

a well-sorted washer load is a well-sorted dryer load).

Large loads of heavy fabrics (like beach towels)

Large, heavy fabrics contain more moisture and take longer to dry. Separate large, heavy fabrics into smaller loads to speed drying time.

 

Controls improperly set

• Match control settings to the load you are drying.

 

 

 

 

Lint filter is full

• Clean lint filter before every load.

 

 

 

 

Blown fuses or tripped circuit

• Replace fuses or reset circuit breakers. Since most

 

breaker

dryers use 2 fuses/breakers, make sure both are

 

 

operating.

 

 

 

 

Overloading/combining loads

• Do not put more than one washer load in the dryer at

 

 

a time.

 

 

 

 

Underloading

• If you are drying only one or two items, add a few items

 

 

to ensure proper tumbling.

 

 

 

The DRy dryness level

Load consists of a mixture

• When combining heavy and light fabrics in a load,

was chosen but load is

of heavy and light fabrics

choose MORE DRy.

still damp

 

 

 

 

 

 

Exhaust system is blocked

• Inspect and clean exhaust system.

 

 

 

Control pads not

Controls accidentally put in

• Press START/PAUSE.

responding

service mode

 

 

 

 

 

Controls accidentally put in

• Hold the LOCK button for 3 seconds to unlock the dryer.

 

lock mode

 

 

 

 

 

Controls performed an

• Reset the in-house breaker.

 

incorrect operation

 

 

 

 

Dryer doesn’t start

Control panel is “asleep”

• This is normal. Press POWER to activate the control panel.

 

 

 

 

Dryer is unplugged

• Make sure the dryer plug is pushed completely into

 

 

the outlet.

 

 

 

 

Fuse is blown/circuit breaker

• Check the building’s fuse/circuit breaker box and

 

is tripped

replace fuse or reset breaker. NOTE: Electric dryers

 

 

use two fuses or breakers.

 

 

 

 

Dryer was accidentally paused

• If the light on the START/PAUSE button is flashing,

 

when starting Delay Start

the dryer is paused. Press START/PAUSE to restart

 

 

the countdown.

No numbers displayed

Dryer is continuously

during cycle, only lights

monitoring the amount of

 

moisture in the clothes

This is normal. When the dryer senses a low level of moisture in the load, the dryer will display the dry time remaining.