Additions to the User Manual

The additions and changes to User Manual 34-SM-25-02 that relate to the newly designed meter body and process heads are given in Table 1 of this addendum.

Use the information in Table 1 to reference and annotate your User Manual.

Table 1 Additions/Changes to the User Manual

Page # in User

Sub-Section

Description of Change

Manual

 

 

 

 

 

15

3.2 Considerations for SMV

The Maximum Working Pressure Rating and the

 

3000 Transmitter

Overpressure Rating has been enhanced for all

 

Table 3 Transmitter

models included in this addendum except for the

 

draft range transmitter.

 

Overpressure Ratings

 

 

 

 

For more information, refer to Table 1 in this

 

 

Addendum.

 

 

 

28

4.5 Piping SMV 3000

In Step 5 of Table 6, do not use the torque

 

Transmitter

 

 

specification of 47.5 to 54 N m(35 to 40 lb-ft).

 

Table 6 Installing ½ inch NPT

Instead, torque Flange Adapter bolts evenly to

 

Flange Adapter

47,5 Nm +/- 2,4 Nm (35 Lb-Ft +/- 1.8 Lb-Ft).

 

 

 

 

 

102

9.3 Inspecting and Cleaning

Do not use specifications for head bolt torque given

 

Barrier Diaphragms

In Step 8 of Table 27.

 

Table 27 Inspecting and

Instead, torque head bolts/nuts to the specifications

 

Cleaning Barrier Diaphragms

given in Table 2 of this addendum.

 

 

 

 

 

110

9.5 Replacing Meter Body

Do not use specifications for head bolt torque given

 

Center Section

In Step 9 of Table 29.

 

Table 29 Replacing Meter Body

Instead, torque head bolts/nuts to the specifications

 

Center Section

given in Table 2 of this addendum.

 

 

 

 

 

143

Replacement Parts

Figure 32 illustrates and Table 38 lists the

 

Figure 32 SMV 3000 Meter

replacement part available for the previous design

 

of the transmitter.

 

Body

 

 

 

Table 38 Parts Identification for

For the newer design, use Figure 1 of this addendum

 

to locate parts, and use Table 3 of this addendum for

 

Callouts in Figure 32

 

 

part numbers and descriptions.

 

 

For applicability of parts, refer to

 

 

34-SM-03-01

 

 

SMV 3000 Smart Multivariable Flow Transmitter

 

 

Specification and Model Selection Guide

 

 

 

147

Wiring Diagrams and Installation

The numbers of installation drawings for transmitter

 

Drawings

models of revision S and greater is given in Table 7

 

 

of this addendum.

 

 

 

2 of 8

34-SM-99-01 (Addendum to 33-SM-25-02)

03/04

Page 206
Image 206
Honeywell SMV 3000 user manual # in User Sub-Section Description of Change