Honeywell SMV 3000 user manual Non-Critical Status Diagnostic Message Table

Models: SMV 3000

1 217
Download 217 pages 57.98 Kb
Page 143
Image 143

11.4 Diagnostic Messages, Continued

Diagnostic Messages,

Table 32

Non-Critical Status Diagnostic Message Table, Continued

continued

 

 

 

 

 

 

 

 

 

 

 

SMV Status

SCT Status Message

SFC Display Message

TDC Status Message

Possible Cause

 

 

 

 

 

9-7

Reynolds Number is Out

-

STATUS 9-7

The high or low Reynolds number

 

 

of Range

 

 

limit was exceeded.

 

 

 

 

 

 

8-7

Sensor Mismatch PV3

SAVE/RESTORE

SNSR MISMTCH PV3

Number of wires selected does not

 

 

TYPE MISMATCH

 

match number of sensor wires

 

 

 

physically connected to the

 

 

 

 

 

 

 

 

transmitter.

What to Do

Verify high or low Reynolds number limit.

Calculate Reynolds number for flow conditions causing the message.

Check sensor wiring and type.

1/99

SMV 3000 Transmitter User’s Manual

131

Page 143
Image 143
Honeywell SMV 3000 user manual Non-Critical Status Diagnostic Message Table