Appendix B– Configuration Record Sheet, Continued

2. Flow - PV4 - Configuration Section

(If using SMV 3000 for PV1, PV2 and PV3 measurement only, do not complete flow section.)

2a. Dynamic Flow Compensation Section

(If you are using a primary element that is not listed, use the Standard Flow Equation Section below.)

Flow Element Type:

Orifice - Flange Taps (ASME-ISO) D >/= 2.3 inches Orifice - Flange Taps (ASME-ISO) 2 </= D </= 2.3 Orifice - Corner Taps (ASME-ISO)

Orifice - D and D/2 Taps (ASME-ISO) Orifice - 2.5D and 8D Taps (ASME-ISO) Venturi - Machined Inlet (ASME-ISO) Venturi - Rough Cast Inlet (ASME-ISO)

Venturi - Rough Welded Sheet-Iron Inlet (ASME-ISO) Nozzle (ASME Long Radius)

Venturi nozzle (ISA Inlet) Leopold venturi Gerand venturi Universal Venturi Tube Lo-Loss Venturi Tube Preso Ellipse Ave. Pitot Tube

_____

_____

_____

_____

_____ (Liquids only)

_____ (Liquids only)

_____ (Liquids only)

_____ (Liquids only)

_____ (Liquids only)

_____ (Liquids only)

_____ (Liquids only)

_____ (Liquids only)

_____ (Liquids only)

_____ (Liquids only)

_____ (Specify 7/8”, 1.25” or 2.25” Probe diameter)

Material ____________

 

 

Bore Diameter (inches at 68 deg. F) ___________

(not required for Pitot Tube)

Design Temperature

______________ (not required for Pitot Tube)

 

Fluid State:

Gas _____

Liquid _____

Steam _____

Flow Data: (obtained from Primary Element Sizing Sheet)

Design Pressure __________________ (required only for Gas applications)

Design Temperature ________________ (required only for Gas applications)

Design Density ___________________ (required only for Steam applications)

Standard Density __________________ (required only for Standard Volume equations)

Fluid Name:

________________________________________________

Pipe Properties:

Material __________

Pipe Schedule ______

Pipe Diameter _________

Isentropic Exponent:

_____________ (not required for Liquid applications or Pitot Tube)

2b. Standard Flow Compensation Section

(Standard equation should be used for any primary element not listed in Dynamic Flow Section above.)

Fluid State:

Gas _____

Liquid _____

Steam _____

Fluid Name:

________________________________________________

Flow Data: (obtained from Primary Element Sizing Sheet)

 

 

Normal Flowrate __________________

Design Pressure

_____________(Gas applications only)

Normal Diff. Pressure_________________ Design Temperature ________________ (Gas applications only)

Design Density ___________________ (required only for Steam and Liquid applications)

Standard Density __________________ (required only for Standard Volume equations)

Flow Compensation:

None ___

Full ___ Pressure Only ___ Temperature Only___