Table 2-17Troubleshooting menu (continued)

Menu item

Sub-menu item

Sub-menu item

Values

Description

 

 

 

 

 

 

Repeat

 

Once (Default)

Determines the number of times the test runs.

 

 

 

Continuous

 

 

 

 

 

 

Print/Stop Test

 

 

Continuous value

Isolate faults by stopping the device during

 

 

 

from 0 to 60,000

the print cycle and observing where in the

 

 

 

milliseconds.

process the image degrades. To run the test,

 

 

 

Default: 0

specify a stop time. The next job that is sent

 

 

 

 

to the device stops at the specified time in the

 

 

 

 

process.

 

 

 

 

 

Color Band Test

Test Page

 

Print

Prints a page that helps identify arcing in the

 

 

 

 

high-voltage power supplies.

 

 

 

 

 

 

Copies

 

Continuous value

Specify the number of copies to print for the

 

 

 

from 1 to 30.

Color Band test

 

 

 

Default: 1

 

 

 

 

 

 

Scanner Tests

Lower Lamp

 

 

A service technician can use this menu item

 

Sensors

 

 

to diagnose potential problems with the

 

 

 

device scanner.

 

ADF Input Motor

 

 

 

 

ADF Input Reverse

 

 

 

 

Flatbed Motor

 

 

 

 

ADF Read Motor

 

 

 

 

ADF Read Motor

 

 

 

 

Reverse

 

 

 

 

ADF Duplex

 

 

 

 

Solenoid

 

 

 

 

ADF LED Indicator

 

 

 

 

 

 

 

 

Control Panel

LEDs

 

 

Verify that the components of the control

 

 

 

 

panel are functioning correctly.

 

Display

 

 

 

 

 

 

 

 

 

 

 

 

Buttons

 

 

 

 

 

 

 

 

 

Touchscreen

 

 

 

 

 

 

 

 

Finisher Tests

Manual Sensor Test

 

 

 

 

 

 

 

 

 

Component Test

 

 

 

 

 

 

 

 

ENWW

Troubleshooting menu 57