Table
Item | Description | |||
|
|
|
|
|
|
| SNMP TEST | YES | This test checks operation of SNMP |
|
|
| NO* | communications by accessing predefined |
|
|
| SNMP objects on the product. | |
|
|
|
| Select YES to choose this test, or NO to not |
|
|
|
| choose it. |
|
|
|
|
|
|
| DATA PATH TEST | YES | This test helps to identify data path and |
|
|
| NO* | corruption problems on an HP postscript level |
|
|
| 3 emulation product. It sends a predefined PS | |
|
|
|
| file to the product, However, the test is |
|
|
|
| paperless; the file will not print. |
|
|
|
| Select YES to choose this test, or NO to not |
|
|
|
| choose it. |
|
|
|
|
|
|
| SELECT ALL | YES | Use this item to select all available embedded |
|
| TESTS | NO* | tests. |
|
|
| Select YES to choose all tests. Select NO to | |
|
|
|
| |
|
|
|
| select individual tests. |
|
|
|
|
|
|
| EXECUTION TIME |
| Use this item to specify the length of time (in |
|
| [H] |
| hours) that an embedded test will be run. You |
|
|
|
| can select a value from 0 to 24 hours. If you |
|
|
|
| select zero (0), the test runs indefinitely until |
|
|
|
| an error occurs or the product is turned off. |
|
|
|
| Data gathered from the HTTP, SNMP, and |
|
|
|
| Data Path tests is printed after the tests have |
|
|
|
| completed. |
|
|
|
|
|
|
| EXECUTE | YES | NO: Do not initiate the selected tests. |
|
|
| NO* | YES: Initiate the selected tests. |
|
|
|
|
|
| PING TEST |
|
| This test is used to check network |
|
|
|
| communications. This test sends |
|
|
|
| packets to a remote network host, then waits |
|
|
|
| for an appropriate response. To run a ping |
|
|
|
| test, set the following items: |
|
|
|
|
|
|
| DEST TYPE | IPV4 | Specify whether the target product is an IPv4 |
|
|
| IPV6 | or IPv6 node. |
|
|
|
| |
|
|
|
|
|
|
| DEST IPV4 |
| Type the IPv4 address. |
|
|
|
|
|
|
| DEST IPV6 |
| Type the IPv6 address. |
|
|
|
|
|
|
| PACKET SIZE |
| Specify the size of each packet, in bytes, to |
|
|
|
| be sent to the remote host. The minimum is |
|
|
|
| 64 (default) and the maximum is 2048. |
|
|
|
|
|
|
| TIMEOUT |
| Specify the length of time, in seconds, to wait |
|
|
|
| for a response from the remote host. The |
|
|
|
| default is 1 and the maximum is 100. |
|
|
|
|
|
|
| COUNT |
| Specify the number of ping test packets to |
|
|
|
| send for this test. Select a value from 0 to 100. |
|
|
|
| The default is 4. To configure the test to run |
|
|
|
| continuously, select 0. |
|
|
|
|
|
ENWW | Control panel menus 37 |