Table 10-1Control-panel messages (continued)

Description

Recommended action

 

 

 

 

 

INCOMPATIBLE FUSER

The incorrect fuser was installed.

CAUTION: The fuser can be hot while the

 

 

product is in use. Wait for the fuser to cool

 

 

before handling it.

 

 

1.

Open the right door.

 

 

2.

Remove the incompatible fuser.

 

 

3.

Install the correct fuser.

 

 

4.

Close the right door.

 

 

 

INCOMPATIBLE SUPPLIES

Print cartridges or other supply items are

Press the OK button to identify the

For status press OK

installed that were not designed for this

incompatible supplies. Install supplies that

product. The product cannot print with these

are designed for this product.

 

supplies installed.

 

 

 

 

 

 

INCOMPATIBLE TRANSFER UNIT

The incorrect transfer unit was installed.

1.

Open right door.

 

 

2.

Remove the incompatible transfer unit.

 

 

3.

Install the correct transfer unit.

 

 

4.

Close the right door.

 

 

 

Incorrect

The PIN is incorrect.

Use the up arrow and down arrow

 

 

buttons to enter the correct PIN.

 

 

 

Initializing

The product is starting.

No action is necessary. Please wait until the

 

 

Ready message appears on the display.

 

 

 

Initializing permanent storage

Displayed when the product is turned on to

No action is necessary.

 

show that permanent storage is being

 

 

 

initialized.

 

 

INSTALL <COLOR> CARTRIDGE

The print cartridge has been removed or has

 

been installed incorrectly.

Replace or reinstall the print cartridge correctly to continue printing. See Replace print cartridges on page 164.

INSTALL FUSER

The fuser has been removed or installed

CAUTION: The fuser can be hot while the

 

incorrectly.

product is in use. Wait for the fuser to cool

 

 

before handling it.

 

 

1.

Open the right door.

 

 

2.

Install or adjust the fuser.

 

 

3.

Close the right door.

 

 

 

INSTALL SUPPLIES

More than one supply is missing or is installed

Press the OK button to identify which supplies

For status press OK

incorrectly.

need to be replaced. Press the OK button a

 

second time for more information about the

 

 

specific supply. Insert the supply item or

 

 

make sure the installed supply item is fully

 

 

seated.

 

 

 

 

INSTALL TRANSFER UNIT

The transfer unit has been removed or

1.

Open right door.

 

installed incorrectly.

2.

Install the transfer unit.

 

 

 

 

3.

Close the right door.

 

 

 

INSUFFICIENT MEMORY TO LOAD

The product does not have enough memory

To continue without this information, press

FONTSDATA

to load the data (for example, fonts or

the OK button . If the message persists, add

 

macros) from the location specified.

more memory.

 

 

 

 

ENWW

Interpret control-panel messages 193