Palette Control ID

The Palette Control ID command specifies the ID number to be used by the Palette Control Command.

?&p#I

 

 

#

=

Palette ID number

Default

=

0

Range

= 0 to 32767 (command is ignored for out-of-range

 

 

values)

The ID number specified by this command is saved as the palette control ID and is used by the Palette Control command (?&p#C).

?E or power-up resets the palette control ID to 0, which is then the default black and white palette ID.

Macros affect the palette control ID value as follows:

Calling a macro—saves the value and restores the value at exit.

Executing a macro—does not save the value; changes remain in effect at exit.

Overlaying a macro—copies the value before resetting to 0, and restores at exit.