Environmental specifications

The following table lists the environmental specifications of HP Workstations.

Table 1-7HP Workstation environmental specifications

Temperature

Humidity

Altitude

Shock

Vibration

Operating: 5 to 35°C (40 to 95°F)

Non-operating: -40 to 60°C (-40 to 140°F)

NOTE: Derate by one degree C (1.8 degrees F) for every 305m (1,000 ft.) altitude over 1,524m (5,000 ft.).

Operating: 8 to 85% Relative Humidity (RH), non-condensing

Non-operating: 8 to 90% Relative Humidity, non-condensing

Operating: 0 to 3,048m (10,000 ft.)

Non-operating: 0 to 9,144m (30,000 ft.)

Operating: ½-sine: 40g, 2-3ms

Non-operating:

½-sine: 160 cm/s, 2-3ms (~100g)

square: 422 cm/s, 20g

NOTE: Values represent individual shock events and do not indicate repetitive shock events.

Operating Random: 0.5g (rms), 5-300 Hz

Non-Operating: random: 2.0g (rms), 10-500 Hz

NOTE: Values do not indicate continuous vibration.

ENWW

Workstation specifications 11

Page 23
Image 23
HP VA799UT 799UT#ABA manual Environmental specifications, 7HP Workstation environmental specifications, Non-operating