Ensuring proper ventilation
Proper ventilation for the system is important for workstation operation. Follow these guidelines to ensure adequate ventilation:
●Operate the workstation on a sturdy, level surface.
●Place the workstation in an area with adequate ventilation. Provide at least 6 inches of clearance at the front and back of the workstation as shown in the following figure.
Your workstation might look different than the one shown. Figure
●Ensure that the ambient air temperature surrounding the workstation falls within the published limit.
NOTE: The ambient upper limit of 35°C is only good up to 5000 feet elevation. There is a 1°C per 1000 feet derating above 5000 feet. So at 10,000 feet the upper ambient air temperature limit is 30°C.
●For cabinet installation, ensure adequate cabinet ventilation and ensure that the ambient temperature within the cabinet does not exceed published limits.
●Never restrict the incoming or outgoing airflow of the workstation by blocking any vents or air intakes as shown in the following figure.
Figure 1-6 Proper workstation placement