IBM RS/6000 7025 manual Runtime Phase

Models: RS/6000 7025

1 364
Download 364 pages 63.22 Kb
Page 351
Image 351

The

SP can dial

a pre-programmed telephone number in the event of an IPL

failure. The SP

issues an error report with the last reported IPL status indi

and

any other

available error information.

ŸUpdate Operator Panel

The SP displays Operator Panel data on the ASCII terminal if a remote connection is active.

ŸEnvironmental Monitoring

Environmental Monitoring is now controlled by the SP instead of the base system, with expanded error recording and reporting.

ŸSystem Firmware Surveillance (Heartbeat Monitoring)

The SP will monitor and time the interval between system firmware heartbeats.

ŸResponding to System Processor Commands

The SP will respond to any command issued by the system processor.

Runtime Phase

This

phase includes the tasks that the SP performs during steady-state execution

the

operating system.

ŸEnvironmental Monitoring

The SP monitors voltages, temperatures and fan speeds (on some servers).

ŸResponding to System Processor Commands

The SP will respond to any command issued by the system processor.

ŸRun-Time Surveillance (Heartbeat Monitoring)

If

the device driver

is

installed and surveillance

enabled, the

SP will monitor

system

heartbeat. If

the

heartbeat times out, the

SP places an

outgoing call.

This

is

different from

the Bringup Phase scenario where two reboot attempts

made

before placing an

outgoing call.

 

 

Appendix E. Service Processor OperationalE-3Phases