4059-XXX

Output Bin Sensor Test

This test is used to verify if the output bin sensors are working correctly.

To run the Output Bin Sensor Test:

1.Select Sensor Test from the Output Bin Test menu.

"Output Bin/Full=OP/Input=OP" message displays.

Full = Output Bins Full Sensor

Pass = Output Bins Pass Thru Sensor

2.Once the message displays, the servicer can manually actuate each of the output bin sensors. The bin full sensor can be actuated by hand, however a sheet of paper can be used to cover the bin's pass thru sensor. When the sensor is closed CL displays, and when the sensor is open OP displays.

3.Press Return/Stop to exit the test.

Output Bin X Sensor Test

Note: Some output expanders have a single output bin sensor installed while others have a dual sensor assembly. Both versions have a single pass thru sensor. This test is used to verify if the Output Bin X sensors are working correctly.

To run the Output Bin X Sensor tests:

1.Select Output Bin tests from the menu.

2.Select Output Bin tests - Sensor Tests.

3.Select Sensor Tests - Output Bin X.

Output Expander with Single Sensor

The following is displayed:

Output Bin X

Full=OP P=OP

Full=Bin Full Sensor

P=Pass Thru Sensor

Diagnostic Aids 3-16

Page 149
Image 149
Lexmark 4059-XXX manual Output Bin Sensor Test, Output Bin X Sensor Test, Output Expander with Single Sensor