4059-XXX
Output Bin Sensor Test
This test is used to verify if the output bin sensors are working correctly.
To run the Output Bin Sensor Test:
1.Select Sensor Test from the Output Bin Test menu.
–"Output Bin/Full=OP/Input=OP" message displays.
–Full = Output Bins Full Sensor
–Pass = Output Bins Pass Thru Sensor
2.Once the message displays, the servicer can manually actuate each of the output bin sensors. The bin full sensor can be actuated by hand, however a sheet of paper can be used to cover the bin's pass thru sensor. When the sensor is closed CL displays, and when the sensor is open OP displays.
3.Press Return/Stop to exit the test.
Output Bin X Sensor Test
Note: Some output expanders have a single output bin sensor installed while others have a dual sensor assembly. Both versions have a single pass thru sensor. This test is used to verify if the Output Bin X sensors are working correctly.
To run the Output Bin X Sensor tests:
1.Select Output Bin tests from the menu.
2.Select Output Bin tests - Sensor Tests.
3.Select Sensor Tests - Output Bin X.
Output Expander with Single Sensor
The following is displayed:
Output Bin X
Full=OP P=OP
Full=Bin Full Sensor
P=Pass Thru Sensor
Diagnostic Aids