4059-XXX

Tray X Empty message displays. Tray does not respond to loading paper. No response from the front door switch.

 

FRU

Action

 

 

 

1

High Capacity Feeder

Check the voltage on the board at

 

Option Control Board

J4-2 (green). The voltage measures

 

 

approximately +5 V dc. If incorrect,

 

 

disconnect the cable at J4 and check

 

 

the voltage again. If incorrect,

 

 

replace the high capacity feeder

 

 

option control board.

 

 

 

2

Elevator Top Optical

Check the continuity of the sensor

 

Sensor Cable

cable. If incorrect, replace the cable.

 

Elevator Top Optical

If correct, replace the top optical

 

Sensor

sensor assembly.

 

 

 

Tray X Paper Low Message displays when the high capacity feeder input tray is full or has adequate paper in the tray.

 

FRU

Action

 

 

 

1

Paper Low Switch

Run the sensor diagnostics for tray X

 

Paper Low Switch Cable

(X=the number that represents the

 

High Capacity Feeder

high capacity input tray). If the test

 

Option Control Board

fails, check the voltage at J3-1

 

 

(grey). The voltage measures

 

 

approximately +24 V dc. If incorrect,

 

 

disconnect the paper low switch

 

 

cable from J3 and measure the

 

 

voltage again on J3-1. If incorrect,

 

 

replace the high capacity feeder

 

 

option control board. If correct,

 

 

check the cable for a short between

 

 

pins 1 and 2 on the cable. If

 

 

incorrect, replace the cable. If

 

 

correct, check the switch for a bent

 

 

or deformed actuator lever or

 

 

defective switch. If incorrect, replace

 

 

the switch.

 

 

 