4059-XXX

 

FRU

Action

 

 

 

5

+5 V dc at the engine board

Check for +5 V dc at the +5 V dc test

 

Test Point

point on the engine board. If correct,

 

 

replace the engine board. If

 

 

incorrect, go to step 6.

 

 

 

6

LVPS Fuse F1

Remove the LVPS from the printer

 

 

and check fuse F1. Replace the fuse

 

 

if the fuse is blown.

 

 

 

7

LVPS Fuse F1 - Continues

Replace fuse F1 if necessary. Turn

 

to blow after LVPS installed

the LVPS on/off switch Off and

 

in the printer.

connect the AC line cord and turn

 

 

the LVPS On.

 

 

CAUTION: Before checking fuse F1

 

 

turn the LVPS Off and disconnect

 

 

the AC line cord. Check fuse F1. If

 

 

the fuse is blown, replace the LVPS.

 

 

 

8

LVPS

Remove the LVPS from the machine:

 

 

CAUTION: Before making any

 

 

measurements on the LVPS output

 

 

connector, observe all necessary

 

 

safety precautions before applying

 

 

AC power. Measure the voltage on

 

 

LVPS output connector CN3. The

 

 

voltage measures +5 V dc. If

 

 

incorrect, replace the LVPS.

 

 

 

2-334059 Service Manual