FRU

Action

 

 

 

3

LVPS

If the +42 V dc test point does not

 

Interconnect Board

measure approximately +42 V dc,

 

 

check the continuity of the cable

 

 

connected between J3 on the fuser

 

 

control and J1 on the interconnect

 

 

board. If the cable does not measure

 

 

continuity, replace the cable. If the

 

 

cable measures continuity, check the

 

 

voltage at CN3-18 on the LVPS. The

 

 

voltage measures approximately

 

 

+42 V dc. If the voltage is correct,

 

 

replace the interconnect board

 

 

assembly. If the voltage is incorrect,

 

 

replace the LVPS.

 

 

 

4

Fuser DC Cable (Engine

Check for continuity of the DC fuser

 

Board to Fuser Board Cable)

cable that is attached between J2 on

 

Engine Board

the engine board and J1 on the fuser

 

 

control board. If the cable does not

 

 

measure continuity, replace the cable.

 

 

If the cable measures continuity,

 

 

replace the engine board.

 

 

 