4059-XXX

 

FRU

Action

 

 

 

3

Stepper Motor Level 1

Check the stepper motor connector

 

 

to ensure it is correctly installed at J4

 

 

on the output expander option board.

 

 

Go to “Output Expander Control

 

 

Board - Level 1 Stepper Motor” on

 

 

page 5-22. If correct, disconnect J4

 

 

from the option board and check the

 

 

resistance of the stepper motor at

 

 

J4:

 

 

J4-1 to J4-2: Approximately 10 ohms

 

 

J4-3 to J4-4: Approximately 10

 

 

ohms.

 

 

Also check each winding for shorts

 

 

between J4-1 thru J4-4 and the

 

 

motor housing. If you find a problem,

 

 

replace the stepper motor. If you do

 

 

not find a problem, replace the

 

 

output expander mechanical linkage

 

 

assembly.

 

 

 

Diagnostic Information 2-82

Page 109
Image 109
Lexmark 4059-XXX manual Go to Output Expander Control