4059-XXX

Cover Open Switch/Cable Service Check

 

FRU

Action

 

 

 

1

Toner Cartridge

Check the toner cartridge to make

 

 

sure it is correctly installed and that

 

 

the right and left hand cartridge

 

 

tracks are not loose or broken.

 

 

Check to make sure the cover open

 

 

switch activation tab on the toner

 

 

cartridge is not broken and that the

 

 

tab correctly activates the cover

 

 

open switch spring.

 

 

 

2

Cover Open Switch/Cable

Check the cover open switch for

 

Assembly

proper mechanical operation. If

 

 

incorrect, repair as necessary.

 

 

Disconnect the cover open switch

 

 

cable from J4 at the engine board

 

 

and measure the voltage at J4-3. It

 

 

measures approximately +5 V dc. If

 

 

the voltage is incorrect, replace the

 

 

engine board. If the voltage is

 

 

correct, check the voltage at J4-1. If

 

 

the voltage measures greater than

 

 

+1.0 V dc, replace the engine board.

 

 

If the voltage is correct, check the

 

 

continuity between J4-1 and J4-3 on

 

 

the cable. If no change in continuity

 

 

occurs as the switch is activated,

 

 

replace the cover open switch/cable

 

 

assembly. If the continuity changes

 

 

as the switch is activated, replace

 

 

the engine board.

 

 

Note: It is easier to check the

 

 

voltages on J4 with the controller

 

 

board removed.

 

 

 

2-314059 Service Manual