4059-XXX

 

FRU

Action

 

 

 

4

LVPS Interconnect Board

Check the +42 V dc test point on the

 

Envelope Conditioner Cable

fuser control board. If the voltage is

 

 

incorrect, check the continuity of the

 

 

envelope conditioner cable. If the

 

 

cable does not measure continuity,

 

 

replace the cable. If the cable

 

 

measures continuity, check the

 

 

voltage at J1-2 on the interconnect

 

 

board. The voltage measures

 

 

approximately +42 V dc. If incorrect,

 

 

check the voltage at CN3-18 on the

 

 

LVPS. It measures approximately

 

 

+42 V dc. If incorrect, replace the

 

 

LVPS. If correct, replace the

 

 

interconnect board assembly.

 

 

 

5

Fuser DC Cable (Engine

Check for continuity of the DC fuser

 

board to Fuser Board cable)

cable that is attached between J2 on

 

Engine Board

the engine board and J1 on the fuser

 

 

control board. If the cable does not

 

 

measure continuity, replace the cable.

 

 

If the cable measures continuity,

 

 

replace the engine board.

 

 

 

2-554059 Service Manual

Page 82
Image 82
Lexmark 4059-XXX manual