4059-XXX

Configuration 2

A level I fuser board and level II engine board are installed in configuration 2.

Note: Check the fuser envelope conditioner solenoid adjustment as described in the adjustment section “Fuser Solenoid Adjustment” on page 4-3.

 

FRU

Action

 

 

 

1

Engine Board Jumpers

Check to make sure a jumper is

 

 

installed between JP1-2 and JP1-3

 

 

and also between JP2-2 and JP2-3 on

 

 

the engine board.

 

 

Note: If the jumpers are not in the

 

 

correct position on the engine board,

 

 

damage can result to the fuser board.

 

 

 

2

Fuser Envelope Conditioner

The operation of the fuser solenoid

 

Solenoid

can be observed by removing the

 

 

redrive assembly. Check for proper

 

 

mechanical operation of the solenoid

 

 

and associated hardware, link and so

 

 

on. If correct, check the resistance of

 

 

the solenoid between J4-1 and J4-2.

 

 

The resistance measures between 5

 

 

ohms and 10 ohms. If the resistance is

 

 

incorrect, replace the solenoid

 

 

assembly.

 

 

 

3

Fuser Control Board

The solenoid receives power from the

 

 

fuser control board. The fuser control

 

 

board receives +42Vdc from the LVPS

 

 

via the interconnect board and

 

 

envelope conditioner cable. Check for

 

 

approximately +42 V dc at the

 

 

+42 V dc test point on the fuser control

 

 

board, If the voltage is incorrect,

 

 

replace the fuser control board.

 

 

 

Diagnostic Information 2-54

Page 81
Image 81
Lexmark 4059-XXX manual Correct position on the engine board