F-70

F-70

TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR

Retest a machine:

If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics. OR

If you repair or replace any electrical components.

ENGINE OUTPUT

Mode

No Load RPM

Load RPM

Low Idle

2150-2250

NA

High Idle

3650-3700

3400-3650

 

 

 

WELDER DC OUTPUT1

Output Control

Range Switch

Open Circuit

Load Volts

Load Amps

 

 

Volts

 

 

Maximum

Maximum

61 - 68

25 - 35

250 - 285

 

 

 

 

 

WELDER AC OUTPUT1

Output Control

Range Switch

Open Circuit

Load Volts

Load Amps

 

 

Volts

 

 

Maximum

Maximum

70 - 76

25 - 35

250 - 305

 

 

 

 

 

WELDER CV OUTPUT1

Output Control

Range Switch

Open Circuit

Load Volts

Load Amps

 

 

Volts

 

 

Maximum

Wire Feed CV High

59 - 62

30 - 34

250 - 280

Maximum

Wire Feed CV Med HI

42 - 45

23 - 26

220 - 240

Maximum

Wire Feed CV Med LO

33.5 - 36

19 - 21

155 - 170

Maximum

Wire Feed CV Low

25 - 27

14.5 - 16

135 - 155

AUXILIARY POWER OUTPUT

 

230 Volt Receptacle

 

 

115 Volt Receptacle2

 

Open Circuit

 

Load Volts

 

Load Amps

Open Circuit

 

Load Volts

 

Load Amps

Voltage

 

 

 

 

Voltage

 

 

 

 

245 - 253

 

210 - 240

 

43 - 48

120 - 127

 

106 - 121

 

78 - 83

 

 

 

 

 

 

 

 

 

 

AMPHENOL AUXILIARY OUTPUT

 

42 Volt Auxiliary

115 Volt Receptacle2

Open Circuit

 

Load Volts

Open Circuit

Load Volts

Voltage

 

 

Voltage

 

43 - 50

 

40 - 48

115 - 126

110 - 126

 

 

FIELD AMPS AND VOLTS

 

Slip Ring Volts

 

Field Amps

 

37 - 47 VDC

 

6 - 6.8 Amps DC

 

 

 

 

1OUTPUT CONTROL switch set at MAXIMUM (position 10).

2Output values of each receptacle can vary within the range shown but must be within 2 volts of each other.

RANGER 10-LX