TROUBLESHOOTING & REPAIR

 

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

FUNCTION PROBLEMS

 

The CV output contactor does not

1. Make sure the Wire Feeder

1. With the jumper installed in pins

pull in when using a wire feeder

switch (S8) is in the “WITH

“D” and “C” in the 14 pin

with a control cable connected to

CONTROL CABLE” position.

amphenol, check for 12VDC

the RANGER 10-LX amphenol.

2. Install a jumper wire from pins

from leads #224F(+) to #2C(-) at

 

the CV output contactor. If

 

“D” to “C” on the 14 pin amphe-

 

12VDC is present and the con-

 

nol. If the output contactor acti-

 

tactor does NOT activate, then

 

vates, the problem is external to

 

the contactor may be defective.

 

the RANGER 10-LX. The wire

 

 

 

feeder or control cable may be

2. If the correct voltage is NOT

 

faulty.

present in Step #1, check from

 

 

lead #224F to ground (lead #5)

 

 

for the presence of 12VDC. If

 

 

12VDC is present, then check

 

 

the continuity of lead 2C

 

 

through the RF bypass board to

 

 

the 14 pin amphenol. See

 

 

Wiring Diagram.

 

 

3. If 12VDC is NOT present from

 

 

lead #224F to ground (lead #5),

 

 

then check the #224F lead for

 

 

an open circuit. See Wiring

 

 

Diagram.

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.