F-19

F-19

 

TROUBLESHOOTING & REPAIR

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

FUNCTION PROBLEMS

 

The CV output contactor does not

1.

Make sure the wire feeder is

1. Remove lead #224F from the

deactivate (drop out) when a wire

 

connected properly

to the

CV output contactor. If the con-

feeder without a control cable is

 

RANGER 10-LX.

 

tactor does not deactivate, the

connected to the RANGER 10-LX.

2.

Make sure the Wire

Feeder

contactor may be faulty. Repair

 

or replace.

 

 

switch (S8) is in the “NO CON-

 

 

 

 

 

TROL CABLE” position.

 

2. The control board may be

 

3.

The CV output contactor will

faulty.

 

 

 

 

normally be activated (closed) if

 

 

 

the Idler switch (S5) is in the

 

 

 

“HIGH” position.

 

 

 

 

 

 

The battery does not stay charged.

1.

Check for loose or faulty con-

1. Perform the Charging Circuit

 

 

nections at the battery and

Test.

 

 

engine charging system.

 

 

2.

The battery may be faulty.

 

 

 

Check or replace.

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

RANGER 10-LX

Page 73
Image 73
Lincoln Electric SVM120-A service manual Perform the Charging Circuit