| TROUBLESHOOTING & REPAIR | |
| TROUBLESHOOTING GUIDE | Observe Safety Guidelines |
|
| detailed in the beginning of this manual. |
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
| |
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION | ||
|
|
|
|
|
| WELDING PROBLEMS |
|
|
|
The welding arc is “cold.” The | 1. Check for loose or faulty con- | 1. Check for the correct open cir- | ||
engine runs normally (3700 RPM | nections at the weld output ter- | cuit voltage (OCV) at the weld- | ||
no load). The auxiliary power is | minals and welding cable con- | ing output terminals. If the cor- | ||
functioning normally. | nections. | rect voltage is present at the | ||
| 2. The welding cables may be too | output terminals, then check for | ||
| loose connections on the heavy | |||
| long or coiled, causing an | |||
| current carrying leads inside the | |||
| excessive voltage drop. | |||
| RANGER | |||
|
| |||
|
| Diagram. |
| |
|
| 2. If the OCV is low at the welder | ||
|
| output | terminals, | perform the |
|
| Engine | Throttle | Adjustment |
|
| Test. |
|
|
|
| 3. Perform the Output Rectifier | ||
|
| Bridge Test. |
| |
|
| 4. Check for shorted or grounded | ||
|
| windings in the reactor and also | ||
|
| in the main stator. See Wiring | ||
|
| Diagram. |
| |
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
RANGER