Lincoln Electric SVM120-A service manual Normal Open Circuit Weld Voltage Waveform High CV Mode

Models: SVM120-A

1 133
Download 133 pages 21.1 Kb
Page 99
Image 99

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-45

F-45

TROUBLESHOOTING & REPAIR

NORMAL OPEN CIRCUIT WELD VOLTAGE WAVEFORM (HIGH CV MODE)

HIGH IDLE – NO LOAD – OUTPUT CONTROL AT MAXIMUM

CH1

0 volts

20 volts

5 ms

This is the typical CV output voltage generated from a properly operating machine. Note that each vertical division represents 20 volts and that each horizontal division represents 5 milliseconds in time.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

20V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

RANGER 10-LX

Page 99
Image 99
Lincoln Electric SVM120-A service manual Normal Open Circuit Weld Voltage Waveform High CV Mode